Problem Solving
975-0187-01-01
4–7
Problem Solving
If the remote display is not functioning, troubleshoot your XC Series using the
tables below. In the event that you have a problem with your XC Series, the
following tables will help you to identify the problem and offer possible solutions to
the problem.
Symptom
Indicator lights do not illuminate when charger is connected to AC power.
Symptom
Fault indicator light illuminates. XC Series stops functioning.
Possible Cause
Solution
No power at AC source and no
battery connected on bank 1
Defective AC wiring
Charger level fault
Ensure that power is available at the source and a
battery or bank is connected on bank 1
Replace wiring
Call for service
Possible Cause
Solution
XC Series does not detect battery
for one of following reasons:
•
poor connection
•
reverse polarity connection
•
damaged wiring
XC Series internal temperature
too hot
Check quality of battery connection and wires.
Ensure correct polarity (negative connected to
negative, positive connected to positive).
Allow the XC Series to cool. Improve ventilation or
install in cooler location.
XC_Charger_Owner.book Page 7 Friday, August 12, 2005 3:23 PM
Summary of Contents for XC1524
Page 2: ...XC_Charger_Owner book Page 2 Friday August 12 2005 3 23 PM...
Page 10: ...viii XC_Charger_Owner book Page viii Friday August 12 2005 3 23 PM...
Page 58: ...3 16 XC_Charger_Owner book Page 16 Friday August 12 2005 3 23 PM...
Page 68: ...4 10 XC_Charger_Owner book Page 10 Friday August 12 2005 3 23 PM...
Page 74: ...A 6 XC_Charger_Owner book Page 6 Friday August 12 2005 3 23 PM...
Page 79: ...XC_Charger_Owner book Page 5 Friday August 12 2005 3 23 PM...