Installation
48
975-0004-01-02 Rev D
DC Load Control Mode Wiring
The procedure below is illustrated in
Figure 2-25
.
To connect the C-Series controller as a DC load
controller:
1.
Connect a cable from the
BAT
POSITIVE
terminal on the
controller to a battery disconnect.
2.
Connect the positive battery cable to the battery
disconnect.
3.
Connect the negative battery cable to the one of the
terminals marked
COMMON
NEGATIVES
.
4.
Connect a cable between the
PV
POS
/
LOAD
terminal on
the controller and the positive terminal on the DC load.
5.
Connect a cable between the controller’s other
COMMON
NEGATIVES
terminal and to the negative terminal of the
load.
6.
Tighten per torque requirements outlined on
page 39
.
Allow a little slack on the cables within the controller and
secure the wiring with strain reliefs.