![Xantrex Trace C35 Owner'S Manual Download Page 43](http://html.mh-extra.com/html/xantrex/trace-c35/trace-c35_owners-manual_881367043.webp)
Adjusting the C-Series Voltage Settings
975-0004-01-02 Rev D
23
For FLOAT charge voltage, the potentiometer scale is
calibrated follows:
•
12-volt system: 12.5 to 14.5 volts
in increments of 0.2 volts,
•
24-volt system: 25.0 to 29.0 volts
in increments of 0.4 volts, and
•
48-volt system: 50.0 to 58.0 volts
in increments of 0.8 volts.
Figure 2-10
Bulk and Float Charge Settings for Charge/Diversion
Control Mode
15.0
13.0
14.0
BULK (CHG)
13.2
13.4
13.6
13.8
14.2
14.4
14.6 14.8
FLOAT (CHG)
14.5
12.5
13.5
12.7
12.9
13.1
13.3
13.7
13.9
14.1 14.3
30.0
26.0
28.0
BULK (CHG)
26.4
26.8
27.2
27.6
28.4
28.8
29.2 29.6
FLOAT (CHG)
29.0
25.0
27.0
25.4
25.8
26.2
26.6
27.4
27.8
28.2 28.6
60.0
52.0
56.0
BULK (CHG)
52.8
53.6
54.4
55.2
56.8
57.6
58.4 59.2
FLOAT (CHG)
58.0
50.0
54.0
50.8
51.6
52.4
53.2
54.8
55.6
56.4 57.2
12-Volt System Settings
24-Volt System Settings
48-Volt System Settings (C40 only)