
©2000 Xantrex Technology Inc.
3.0 INSTALLATION
22
Grounding
The C-series controllers are designed to work with both negative ground
and ungrounded electrical systems. The metal chassis of this charge/load
controller must be grounded for either system by connecting it with a copper wire
to a grounding electrode such as a ground rod driven into the earth.
If a negative ground system is desired, connect the negative current
carrying conductor to the grounding system at one point in the system. Consult
local and national electrical codes for more information and any additional
requirements.
Summary of Contents for Trace C35
Page 2: ...2000 Xantrex Technology Inc...
Page 55: ......