Equalization Mode Indication
Alternating Red and Green
The controller is in the EQUALIZE mode. It will automatically stop the
equalization process after accumulating two hours of operation at a voltage
above the BULK setting. The user can stop the equalization process at any time
by pressing the reset switch until the status LED stops alternating red and green.
Error Mode Indication
Fast Blinking Orange
The controller detected an over-current or an over-temperature condition
and the loads are disconnected. The controller will try to automatically restart
the loads after a 6-minute delay. If the controller will not restart, turn off all
loads and press the reset switch. If it then restarts, the loads may be too large.
A delay up to five seconds may occur before the controller attempts to restart
after pressing the reset switch.
2.0 FEATURES
9