©2002 Xantrex Technology Inc. All Rights Reserved
P/N 973-0019-01-02 Rev A 06/2002
9
Figure 5
Wiring TFBs to the Battery, DC Disconnect, and Inverter
Installation (continued)
Wiring TFBs to the Battery, DC Disconnect, and Inverter
+
-
BATTERY
INVERTER
TFB FUSE BLOCK FOR
C-TYPE
BATTERY CABLES
F
U
SE
C
L
AS
S
T
300
A
M
P
*DC
DISCONNECT
*DC DISCONNECT MAY NOT
BE REQUIRED IN ALL
APPLICATIONS
+
-
BATTERY
TFB FUSE BLOCK
FOR RING-LUGGED
BATTERY CABLES
INVERTER
F
U
SE
C
L
AS
S T
300
A
M
P
*DC
DISCONNECT
*DC DISCONNECT MAY NOT
BE REQUIRED IN ALL
APPLICATIONS