3. Mount the solar panel.

T1:

20 lb-in

Torque

2.3 N-m

T2:

Depends on

roof material

Torque

TIP:

Contact the vehicle/vesselmanufacturer

for recommendations on roof sealant.

a.

Unpack the solar panels and prepare all installation tools and
materials.

b.

Prepare the mounting surface by removing dust, dirt, and
debris.

NOTICE

GENERAL PRECAUTIONS

l

Select a mounting surface on the roof of your vehicle that is
firm, thick, rigid, and able to support the solar panel and
mounting hardware.

l

Do not select a roof location within 1 m (3 ft) of the front of
the vehicle to reduce wind lift forces during motion.

l

Do not mount the solar panel near other roof fixtures that can
obstruct direct exposure to sunlight.

Failure to follow these instructions can result in physical
damage to vehicles and property.

c.

Install the mounting brackets on the solar panel. See

T1

.

d.

Place the solar panel assembly on the planned location on the
roof, mark the locations of mounting bracket holes on the roof
of the vehicle, pre-drlll the two holes [one (+), one (–)].

e.

Apply a silicon outdoor-rated, waterproof sealant around the
pre-drilled holes.

f.

Install the solar panel assembly on the roof and fasten the
brackets using the supplied #10 screws. See

T2

.

g.

Apply a silicon outdoor-rated, waterproof sealant to the screw
heads.

975-0808-01-01 Rev E

January 2021

7

Summary of Contents for SOLAR 780-0100

Page 1: ...es and store energy to a battery during daylight hours The Xantrex Solar Panel base package includes the following items n one 100W or 160W Xantrex Solar Panel n one Installation Guide n one set of mo...

Page 2: ...the solar panel except where noted for connecting wiring and cabling See your warranty for instructions on obtaining service Attempting to service the solar panel yourself may result in a risk of ele...

Page 3: ...ation Steps 5 Safety Instructions 5 Tools and Materials 5 Solar Panel Wiring 9 Solar Panel Maintenance and Care 11 Troubleshooting 12 Common Issues 12 Specifications 13 Accessory List 14 975 0808 01 0...

Page 4: ...This page is intentionally blank...

Page 5: ...regulations n Disconnect all power sources n Disable and secure disconnect devices Failure to follow these instructions can result in death serious injury or equipment damage Tools and Materials You m...

Page 6: ...ea that is readily accessible viewable and free from exposure to moisture c Plan the route and measure the lengths of cables needed to reach their connection points factoring in bends and slack d You...

Page 7: ...ce wind lift forces during motion l Do not mount the solar panel near other roof fixtures that can obstruct direct exposure to sunlight Failure to follow these instructions can result in physical dama...

Page 8: ...te the PV cables through the roof entry point and connect the red pos and black neg PV cables to the charge controller See T3 d Connect the red pos and black neg battery cables to the charge controlle...

Page 9: ...power point tracking 30A 12 24VDC 710 3024 01 b Solar panels can be configured in series parallel or a combination of both series and parallel Figure 2 Cable schematic for series Pos of first panel co...

Page 10: ...rst panel connects to Neg of next panel using branch connectors and so on and terminating with the Neg of the solar charge controller Optimized for MPPT or PWM solar charger Figure 4 Cable schematic f...

Page 11: ...anels The power output of a solar panel is proportional to the amount of sunlight that reaches the solar cells Therefore any build up of dust or dirt on the surface of the solar panel will result in a...

Page 12: ...ion on page 1 Common Issues Problem Possible Cause Solution Battery does not get charged even when sunlight is present Solar panel is partially shaded or there is insufficient sunlight Move the vehicl...

Page 13: ...00 VDC Safety ETL listed to UL 1703 and CAN ULC ORD C1703 Class III PV Module 160W Solar Panel Part number 780 0160 Dimensions 53 2 26 9 1 4 inches 1350 670 35 mm Unit weight 23 2 lbs 10 5 kg Cell Typ...

Page 14: ...0050 PV Connector Assembly Tool PN 708 0060 Mounting Hardware PN 708 0070 Remote Battery Temperature Sensor PN 708 0080 Roof Entry Cable Plate PN 708 0090 Solar and Battery Cables Starter Kit 10 AWG 2...

Page 15: ...This page intentionally left blank...

Page 16: ...1 800 670 0707 1 408 987 6030 customerservice xantrex com http www xantrex com power products support http www xantrex com 975 0808 01 01 Rev E January 2021 Printed in USA...

Reviews: