Safety
x
975-0288-01-01
If hardwired......
To Power Down the PowerHub 1800:
WARNING: Shock Hazard
If no DC Disconnect is used, then the DC input generators (solar or wind) will
have to be physically disconnected to ensure power is OFF.
Figure iii
Power Down Procedure for Hardwired Installations
1
2
3
6
4
5
Disconnect any loads directly
connected to the front panel of
the PowerHub
Press ON/OFF
Switch to turn OFF
Inverter/Charger
Disconnect the Utility
power by opening the AC
input circuit breaker in the
main panel.
Disconnect the Battery Box(es)
from the Inverter
Disconnect Loads connected to
the PowerHub through AC
Distribution Panel (Sub-panel)
by opening the Inverter Output
Circuit Breaker.
Disconnect the
DC Input.(s)
Summary of Contents for PowerHub PH1800