Front Panel Display Screens and What They Mean
975-0334-01-01
5–5
Additional screens
for multiple units
In addition to the normal system message screens, additional screens specific to
each GT Inverter unit can be displayed when the unit is networked to other GT
Inverters. These screens are only available on multiple unit systems.
To view unit-specific screens in a multiple unit system:
1. Tap the inverter front panel to advance the display to the next screen.
Continue tapping until the final system message screen (“Grid Readings”, in
Table 5-3 above) is displayed.
2. Tap again. Normal operation screens shown in Table 5-4 are displayed in the
order given, as you tap successively on the unit.
If you continue to tap the unit, the LCD will cycle through all of the available
normal operation screens. Each message is displayed for up to 30 seconds. If you
do not tap again within that time period, then the LCD backlight turns off and the
display reverts to the default normal operation screen (Table 5-2).
Table 5-3
Normal Operation Screens
Tap
Display*
* In a multiple unit system with network cables properly installed, the system
values displayed are for the entire system. For example, in a two-inverter
system, if inverter #1 is producing 1500 W and inverter #2 is producing
2000 W, both inverters display a total system power of 3500 W. Time online
and array readings are for the local inverter and PV array associated with that
inverter.
Description
1st time
System 5000W
Today 2.500kWh
LCD backlight turns on for better readability
and default Normal Operation screen is
displayed.
2nd time
System Lifetime
305kWh
Lifetime energy produced by the GT Inverter
system.
3rd time
Time Online
Today hh:mm:ss
Length of time inverter has been online today, in
hours (hh), minutes (mm) and seconds (ss).
4th time
Array Readings
350.5V
8.4A
Immediate DC voltage and current readings
from the PV array.
5th time
Grid Readings
242.6V
60.0Hz
Immediate AC voltage and frequency readings
from the Grid
Table 5-4
Additional Normal Operation Screens for Each GT Inverter Unit in a
Multiple Unit System
Tap
Display
Description
6th time
Unit 5000W
Today 1.250kWh
Power being produced by this unit now.
Cumulative energy produced by this unit today.
7th time
Unit Lifetime
150kWh
Lifetime energy produced by this GT Inverter unit