System Specifications
975-0767-01-01
95
System Specifications
Freedom X 1200
Transfer relay rating (A
a
)
30A surge (24A continuous)
Transfer time (milliseconds
b
)
Shore to inverter:
Inverter to shore:
<20 milliseconds
<20 milliseconds with a 20-
second delay
Transfer voltage (V)
Shore to inverter:
Inverter to shore:
<95 V and >135 V
<130 V and >100 V
Cooling
Fan, activated by any of the
following:
High internal temperature
High AC output power
Table 17 System specifications
a
Circuit breakers shall not carry more than 80% of their UL current rating continuously.
b
To change the AC Transfer time (mode), see
Adjusting Feature Settings in Configuration Mode on page
Freedom X 1200
Operating voltage range
LBCO voltage
a
–16.5 VDC
Maximum non-operating voltage 0–24 VDC
Nominal voltage
12.0 VDC
Nominal current at full load
116 ADC
Table 18 DC input for inverting
a
To set LBCO, see
Adjusting Feature Settings in Configuration Mode on page 1
.