975-0545-01-01
37
Configuration
Batt Type
Full name
Battery Type
Configurable setting
Select the type of battery from flooded, custom,
AGM, or gel. If a battery temperature sensor is not present, the Freedom
SW 3000 uses the hot setting which is the default value, unless the setting
has been adjusted during configuration.
When to use
This setting is adjusted for the type of battery you have. It is
important during installation to choose the correct setting (battery type) to
optimize the charge algorithm for your battery and to properly enable or
disable equalization. See “Battery Charging Reference” on page 55.
The custom setting is selected to get the battery settings programmed by the
dealer.
Batt Size
Full name
Battery size
Configurable setting
This features let you select the size of the battery
bank being charged.
You can adjust the Battery Size settings as follows:
When to use
Adjust this setting to your actual battery bank size.
Outcome
Reduces the maximum charger current to protect against
charging smaller batteries too aggressively. This setting charges batteries
appropriately based on capacity. (See the Battery Information section in the
FSW3000 Sine Wave Inverter/Charger Installation Guide
for more
information.)
Clear Faults
Purpose
Clear Faults is a command which clears all active faults in the
Freedom SW 3000. When faults are cleared, the device will resume normal
operation. If the fault condition still exists, the fault will reoccur. See
“Fault
Types” on page 45
for an explanation of faults.
You can adjust the Clear Faults settings as follows:
Batt Type
[Flooded]
Batt Size
[440 Ah]
Range of values
Increment
Default
50 Ah to 2000 Ah
10 Ah
440 Ah
Clear Faults
Value
Effect
Yes
Faults are cleared
No
No action