975-0123-01-01 Rev A
5
The Liquid Crystal Display (LCD)
The LCD on the faceplate or remote provides the following information.
The contrast of this display can be adjusted by a potentiometer located
on the back on the unit. The potentiometer is a black, round knob on the
circuit board next to the jumper pins. See
page 9
for the location of this
potentiometer.
Information Type
Display Value/Range
Current from PV Array or DC Load
0 to 85 amps DC (in whole numbers only)
Battery Voltage
4 to 100 volts DC (in 0.2 volt increments)
Watts
0 to 3,600 watts (volts x amps)
Amp hours
0 to 65,536 Ah; can be reset to 0
Total amp hours
0 to 65,536 Ah; resets to zero when power
is disconnected
Status LED
green, red, or orange
Figure 3
LCD Features
0 1 . 0
0 0 1 3
1 3 . 1
0 0 0 0 4 . 3
0 0 0 1 3 . 2
Amps
Volts
Watts
Total Amp Hours
Amp Hours
Amps displayed in
whole numbers only