![Xantrex 880-0125-12 Owner'S Manual Download Page 15](http://html1.mh-extra.com/html/xantrex/880-0125-12/880-0125-12_owners-manual_3164057015.webp)
Discharging
Features
Temperature range
-20 – 55 °C (-4 – 131 °F)
Output voltage
11.2 to 14.6 V
Discharge current
≤80A (recommended)
Max discharge current
100A with starting temp of 77°F (25°C)
(continuous)
Surge discharge current
<400A for 30s max with starting temp of 77°F
(25°C)
Pulse discharge current
<1000A for 1s max with starting temp of 77°F
(25°C)
Reserve cut-off voltage
12.0V ±0.05V
Discharge cut-off voltage
11.2 ±0.1V
Self-
discharge
rate
Residual capacity
≤3% per month; ≤15% per year
Reversible capacity
≤1.5%per month; ≤8% per year
Storage
Recommended temperature and
humidity
15 to 35°C (59 to 95°F)
,
45 to 75
%
RH
Temperature range
< 1 Month, -20 to 35°C (-4 to 95°F)
< 3 Months, 10 to 30°C (14 to 86°F)
For long term storage, see the
Battery Storage
Guide (doc number 975-1005-01-01)
.
Others
Battery cells are recognized components under UL1642 standard and representative
cells have been evaluated to IEC 62619 standard.
975-0824-01-01 Rev A
February 2020
15