600 feet max (183 m)

D

400 feet max (122 m)

MRC44CB1

IR Receiver

781RG 

Power Supply

PWR

IR IN

CONTROLLER

KEYPAD

+12V  GND  SIG

JP1

LED1

 

 

Figure 2d – Example D 

 

EXAMPLE D 
EXTENDING THE OVERALL LENGTH BETWEEN MRC44 KEYPADS 

 
This is applicable when the overall distance between the MRC44 Controller and the last MRC44 Keypad in the chain is greater 
than 200ft. 

1.  Remove the jumper across JP1 on the MRC44CB1 connecting block 
2.  From the Primary MRC44 Keypad, run a CAT5 to the location where the MRC44CB1 connecting block will be 

located. 

Note: The Primary Keypad must be within 400ft of the MRC44 Controller 

3.  Mount MRC44CB1 to a convenient location using the Adhesive strip supplied 
4.  Properly terminate both ends of the cable with RJ45 connectors. Plug one end into the connector labeled 

Expansion

 

on the MRC44 Keypad and the other end into the connector labeled 

Controller

 on the MRC44CB1 connecting block. 

5.  Run another CAT5 cable from the MRC44CB1 connecting block to the location of the next keypad (up to 250 ft.) and 

properly terminate both ends with RJ45 Connectors 

6.  Plug one end into the connector labeled 

Keypad

 on the MRC44CB1 and the other end into the connector labeled 

Controller

 on the MRC44 Keypad 

7.  Plug a 782-00 Power Supply into the 2.5mm Coaxial jack on the MRC44CB1 connecting block labeled 

PWR

 

 
CAUTION! 

Do not plug in a 781RG or any other Power Supply into the MRC44CB1 when a jumper is placed across JP1. 

 

TROUBLESHOOTING 
 

1.  Power Supply getting warm: 

a.  When using external power supply, make sure 

jumper is removed

 from 

JP1 

on the MRC44CB1 Connecting 

Block 

b.  Check for wiring problem either on MRC44CB1 connecting block or in RJ45 CAT5 Terminations 

2.  IR Receive Confirmation LED lights on MRC44CB1 when IR signal transmitted, but emitters do not flash at MRC44 and 

no control of external sources. All control works fine when controlling from MRC44 Keypads. 

a.  CAT5 RJ45 connection at last keypad is plugged into 

EXPANSION

 connector instead of 

KEYPAD

 

b.  Check for wiring problem either on MRC44CB1 connecting block or in RJ45 CAT5 Terminations 

3.  Still getting IR Interference even when using “CFL Friendly” or “Plasma Friendly” IR Receiver: 

a.  IR Receiver on MRC44 Keypads needs to be disabled. Remove jumper across 

Sensor Enable

 pins on rear of 

MRC44 Keypad (refer to MRC44 Instruction Manual) 

b.  Check for wiring problem either on MRC44CB1 connecting block or in RJ45 CAT5 Terminations or interference 

from adjacent cable runs, Dimmer Controls etc. 

 

 

 
 
 
 

 
 
 
 
 
 

 
 
 

XANTECH CORPORATION 

12950 Bradley Avenue, Sylmar CA 91342-3829 

phone 818.362.0353 • fax 818.362.9506 

 

Part No. 08901185 Rev A 08-05-2002

 