background image

Model MRC44CB1 

 

Page 3 

 

© 2002 Xantech Corporation

 

3.  If overall distance from MRC44 Controller to secondary zone location is less than 200ft., you may power Secondary 

Keypad/IR Receiver from the Primary Keypad. In this case, install a jumper across 

JP1

 on the MRC44CB1 

Connecting block. 

Note: If overall distance from MRC44 to secondary zone is greater than 200ft., an external 781RG power supply 
will be required. In this case REMOVE JUMPER across JP1 on MRC44CB1 and connect supply to 2.5mm coaxial 
jack. 

4.  Properly terminate wire with RJ45 connector and connect to the connector labeled 

Controller

 on the MRC44CB1 

5.  Run 3-conductor wire from MRC44CB1 Connecting block location to Secondary Keypad or IR Receiver location. 
6.  Connect one end of the 3-conductor cable to the 

V G S

 terminals of the MRC44CB1 connecting block and the other 

end to the proper 

+12v, IR Out, 

and 

GND 

terminals of the desired Keypad or IR Receiver. 

Note: If IR Receiver is being connected with a 3.5mm ‘Quick Connect’ plug, simply insert plug into jack labeled IR 
IN on MRC44CB1 

 

FOUR ZONE - FOUR SOURCE AUDIO/VIDEO CONTROLLER/AMPLIFIER

MRC44

1

2

3

4

POWER

POWER

CH

CH

STATUS

SELECT

PLAY

STOP

PAUSE

FF

REW

VOL

VOL

MUTE

POWER

CH

CH

STATUS

SELECT

PLAY

STOP

PAUSE

FF

REW

VOL

VOL

MUTE

200 feet max (61 m)

MRC44CB1

C

IR Receiver

781RG 

Power Supply

PWR

IR IN

CONTROLLER

KEYPAD

+12V  GND  SIG

JP1

LED1

 

 

Figure 2c – Example C 

 
EXAMPLE C 
ADDING AN IR RECEIVER TO A ZONE WITH A MRC44 KEYPAD 

 
This is applicable if the IR Receiver needs to be in a different location than the Keypad/s 

or

 if a “CFL Friendly” or “Plasma 

Friendly” IR Receiver is required. 

1.  Mount MRC44CB1 to a convenient location using the Adhesive strip supplied 
2.  If only one IR Receiver is to be added, you may power this from the MRC44 Controller. In this case, place a jumper 

across JP1 on the MRC44CB1 connecting block. 

3.  From the Primary MRC44 Keypad, run a CAT5 cable to where the IR Receiver will be located. 
4.  Properly terminate both ends of the cable with RJ45 connectors. Plug one end into the connector labeled 

Expansion

 

on the MRC44 Keypad and the other end into the connector labeled 

Controller

 on the MRC44CB1 connecting block. 

5.  If IR Receiver is equipped with a 

“quick connect”

 3.5mm connector, plug directly into the jack labeled 

IR IN

 on the 

MRC44CB1. If the IR Receiver has “stripped” ends, plug the appropriate wires into the 

V, G, 

and 

S

 terminals. 

6.  If another MRC44 Keypad is being used, run another CAT5 cable from the MRC44CB1 connecting block to the 

location of the next keypad and properly terminate both ends with RJ45 Connectors

 

7.  Plug one end into the connector labeled 

Keypad

 on the MRC44CB1 and the other end into the connector labeled 

Controller

 on the MRC44 Keypad

 

 
Note: If the overall distance between the MRC44 Controller and the last Keypad in the line is greater than 200ft., 
an external power supply will be needed. In this case, remove the jumper across JP1 and use a 782-00 Power 
Supply connected to the MRC44CB1 connecting block. 

 