USING THE STATUS LED INDICATOR 

The 780-95 

Plasma Friendly

 IR Receiver includes a Status LED located just below the Talkback LED (See 

Fig. 1

). This permits the 

system to have a visible power ON/OFF indicator in the remote room. 
 
When used with any of Xantech’s 

W

hole-house 

A

udio 

V

ideo 

E

ntertainment systems such as the MRC-88, MRC-44 (MRC44CB1 

required) or the ZPR68-10 Pre-Amp as part of the normal 

4-wire

 hookup, connect the terminal marked STATUS on the 780-95 

Plasma 

Friendly

 IR Receiver to the appropriate Zones STATUS (or CO) connection on the MRC or ZPR system controller. See 

Figure 5

 below. 

This will give visual ON/OFF status of the associated zone on the AV System Controller.

 

 

ZONE  CONTROL - IR INPUTS

+12V

GND

STATUS

IR IN

IR OUT
GND
STATUS
+12V

Hand Held

Remote

GND

IR OUT

+12V

780-95

Plasma-Friendly

J-Box

IR Receiver

(rear view)

4-Conductor

Inter-room Cable

(unshielded OK)

MAIN ROOM

REMOTE ROOM

STATUS

V

G

ST

S

Add resistor in series

with Status line to

adjust brightness, if required.

(See Note*).

780-95

IR RECEIVER

ZPR68-10

Zone Control - IR Inputs section

®

 

 

Figure 5 – Interfacing STATUS connection of 780-95 with Zone STATUS line on ZPR68-10 

 

In Single Zone systems, the Status LED could show the ON/OFF status of an AV Receiver. To achieve this, simply plug a 12vDC 
adapter, such as the Xantech 786-00 Power Supply, into the 

switched

 AC Outlet of the AV Receiver. The 12v 

‘+’ 

and 

‘-’ 

leads are then 

connected between the STATUS (

‘+’

 lead) and GND (

‘-’

 lead) terminals of the 780-95. The Connecting Block makes a convenient tie-

line for extending leads of the Power Supply to the actual terminals of the 780-95 as shown in 

Figure 6

.   

 

IR OUT
GND
STATUS
+12V

283M

 Blink-IR™

Mouse Emitter

To 120 VAC

(unswitched)

781RG

Power Supply

283M

 Emitter

283M

Emitter

Hand Held

Remote

VCR

GND

IR OUT

+12V

780-95

Plasma-Friendly

J-Box

IR Receiver

(rear view)

4-Conductor

Inter-room Cable

(unshielded OK)

STATUS

Positive Side ("+")

786-00

Power Supply

(12V at 10 mA)

Activates STATUS

LED on 780-90 when

AV Receiver is

powered ON

Plug into

Switched AC Outlet

on A/V Receiver

(see text)

Add resistor in series

with Status line to

adjust brightness, if desired.

(See Note*).

REMOTE ROOM

MAIN ROOM

– +

789-44

Connecting Block

780-95

IR RECEIVER

®

12VDC

+12 VDC

GND
STATUS
IR IN

EMITTERS

IR

RCVR

789-44

CONNECTING BLOCK

®

Satellite Receiver

A/V 

Receiver

 

 

Figure 6 – Interfacing STATUS connection of 780-95 to Switched Outlet of AV Receiver 

 
 
 

 

 

XANTECH CORPORATION 

13100 Telfair, Sylmar CA 91342 

Phone 818.362.0353 • fax 818.362.9506 

Part No. 08905035 Rev A  09-14-2004 