background image

Model 780-95 

 

Page 3 

 

 

 

 

© 2003 Xantech Corporation

 

 
APPLICATION WIRING 

typical system

, with a 780-95, 781RG Power Supply and 283M Emitters plugged into a 789-44 Connecting Block, is shown in 

Figure 3

1.  Wire the appropriate leads of the 3 or 4-conductor cable from the 780-95 to the +12VDC, GND, STATUS (if applicable), and IR 

IN terminals on the 789-44 Connecting Block 

2.  Plug in the 3.5mm mono mini plug from any of the 282, 284, 283 and 286 series Emitters into the jacks labeled EMITTERS on 

the 789-44 Connecting Block and affix the opposite end to the IR Sensor Window of the controlled equipment. 

3.  Plug in the 2.1mm Coaxial power plug of the 781RG Power Supply (not included) into the jack labeled 12VDC on the 789-44 

Connecting Block. 

4. 

Plug the AC end of the 781RG power Supply into an ‘un-switched’ 120VAC outlet.

 

 

IR OUT
GND
STATUS
+12V

283M

 Blink-IR™

Mouse Emitter

To 120 V AC

(unswitched)

781RG

Power Supply

789-44

Connecting Block

283M

 Emitter

283M

 Emitter

REMOTE ROOM

MAIN ROOM

Hand Held

Remote

VCR

GND

IR

OUT

+12V

780-95

Plasma-Friendly

J-Box

IR Receiver

(rear view)

3-Conductor

Inter-room Cable

(unshielded OK)

780-95

IR RECEIVER

®

12VDC

+12 VDC

GND
STATUS
IR IN

EMITTERS

IR

RCVR

789-44

CONNECTING BLOCK

®

Satellite Receiver

AV 

Receiver

 

Figure 3 - Typical System Layout using 780-95, 789-44, 781RG, and 283M Emitters

 

 

ADVANCED WIRING CONFIGURATION 

780-95 may also be used in conjunction with other Xantech IR Receivers by simply wiring in parallel on a Connecting Block such as the 
791-44 Amplified Block as shown in Figure 4 below. 
  

1.  Connect all IR Receivers in parallel at the terminals of the connecting block as shown in 

Figure 4

 below. 

2.  Plug in the 2.1mm Coaxial power plug of the 781RG (or 782) Power Supply (not included) into the jack labeled PWR on the 

789-44CB. 

NOTE: 

Up to 7 IR Receivers may be connected in parallel with a single 781RG power supply. If more IR Receivers or any Keypads 

are required, check total current requirements and increase power supply current rating accordingly; i.e. 782-00 - 1.2A power 
Supply) 

3. 

Plug in the Emitters 3.5mm mono mini plug (282, 284, 283 or 286 series) into the Emitter Outputs on the 791-44.

 

 

283M

Blink-IR™

Mouse Emitter

To 120 V AC

(unswitched)

781RG

Power Supply

283M

 Emitter

283M

 Emitter

283M

 Emitter

283M

 Emitter

VCR

Cassette DecK

GND

+12V

490-00 

Series

Micro Link™

IR Receivers

3-Wire

Cable

IR

OUT

GND

+12V

Red

Stripe

3-Wire

Cable

IR

OUT

GND

+12V

480-00

Dinky Link™

IR Receiver

Red

(or white)

Stripe

REMOTE ROOM 1

780-80

CFL-Friendly

J-Box IR Receiver

780-95

Plasma-Friendly

J-Box IR Receiver

7 Foot 3-Conductor

Cable with Quick

Connect Stereo

Mini Plug

490-30 

Series

Micro Link™

IR Receivers

MAIN ROOM, EQUIPMENT AREA, ETC.

REMOTE ROOM 2

REMOTE ROOM 3

REMOTE ROOM 4

GND

IR

OUT

+12V

3-Conductor

Room-to-

Room Cables

(Home Runs)

IR OUT
GND
STATUS
+12V

791-44

Amplified Connecting Block

780-80

IR RECEIVER

®

780-95

IR RECEIVER

®

Satellite Receiver

AV 

Receiver

CD Changer

+12 VDC
GND

EMITTERS

12 VDC

HIGH

IR

OUT

STATUS
IR IN

IR

RCVR

791-

44

AMPLIFIED

CONNECTING BLOCK

®

IR

OUT

IR OUT
GND
STATUS
+12V

 

 

Figure 4 - Advanced Wiring Configuration using 780-95, 791-44, 781RG Power Supply and multiple 283M’s 

 

 

CAUTION:

  With any of these systems, be sure the 781RG (or 782-00) Power Supply is plugged into an un-switched AC outlet. This 

maintains the 780 system in "stand-by" operation so that power-on commands can be sent to the controlled equipment.  

Reviews: