background image

Page 4 

 

Model 490-95 

 

 

 

© 2004 Xantech Corporation 

291-10

IR Receiver

+12 VDC

IR OUT

GND

780-10

J-BOX RECEIVER

®

Satellite Receiver

AV 

Receiver

VCR

MAIN ROOM 1, EQUIPMENT CABINET, ETC.

282M

Mouse Emitter

282M

Emitter

283M

Blink IR Emitter

GND

IR OUT

+12V

780-10

J-Box

IR Receiver

3-Wire

Cable

IR OUT

GND

+12V

480-00

Dinky Link™

IR Receiver

Red

Stripe

GND

IR OUT

+12V

286M

Dual Blink IRs

(to other

controlled

devices)

Hand Held

Remote

CB12

Connecting

Block

OUT

V G S

IR

RCVR

PWR

ROOM 2

(See Text)

X    X

3-Conductor Room-to-Room Cable

24 to 18 gauge (unshielded OK)

Smart

Pad™

789-44

Connecting Block

To 120 V AC

(unswitched)

782-00

Power

Supply

ROOM 4

ROOM 3

12VDC

+12 VDC

GND
STATUS
IR IN

EMITTERS

IR

RCVR

789-44

CONNECTING BLOCK

®

490-95

Plasma-Friendly

IR Receiver

 

 

Figure 4 - Advanced Wiring Configuration using 490-95, CB12, 789-44, 781RG and multiple 286M’s 

 

5.  If a local Emitter is needed on the CB12, you will need to place a 470 Ohm Resistor in Series with the Signal 

Output on the CB12. To Wire in this fashion: 

a.  Cut a standard Mouse Emitter (282M or 283M) approximately 12inches from the 3.5mm Mono Mini Jack. 

You will now have 2 cables; one with a 3.5mm Mono Mini Jack and one with the Mouse Emitter.  

b.  Wire the 2 leads of the Mono Mini Jack side to a terminal Strip.  
c.  On the Terminal Strip, opposite the lead with the White Stripe (Signal) connect one side of the 470 Ohm 

Resistor.  

d.  Wire the other side of the resistor to the lead with the White Stripe on the Mouse Emitter.  
e.  Connect the Black Wire of the Mouse Emitter to the Terminal Strip opposite the Black Wire (GND) from 

the 3.5mm Mono Mini Jack.  

This will keep the proper load balance and prevent miscommunication with the Emitters on the 789-44 CB. 

 

3.5MM MINI PLUG PINOUT 

There might be times when the 490-95 needs to be wired directly to a Terminal Block. In that case you will need to cut off 
the 3.5mm jack and wire according to 

Table 1

 

Table 1 - 490-95 Connector Pin-Out 

PLUG 

CABLE LEADS

CIRCUIT ITEM 

TIP WHITE  IR 

OUT 

RING BLACK  GROUND 

SLEEVE RED 

+12V 

 

 

CAUTION:

  With any of these systems, be sure the 781-RG Power Supply is plugged into an un-switched AC outlet. This 

maintains the 490 system in "stand-by" operation so that power-on commands can be sent to the controlled equipment.  

 
 

XANTECH CORPORATION 

13100 Telfair Avenue, Sylmar CA 91342-3829 

phone 818.362.0353 • fax 818.362.9506 

Part No. 08901485 Rev A 07-22-04 