APPLICATION WIRING 

typical system

, with a 490-95, 781RG Power Supply and 283M Emitter plugged into a 789-44 Connecting Block, is 

shown in 

Figure 3

1.  Plug in the 2.1mm Coaxial power plug of the 781RG Power Supply (not included) into the jack labeled 12VDC on 

the 789-44 Connecting Block. 

2.  Plug the AC end of the 781RG power Supply into an ‘un-switched’ 120v AC Line outlet. 
3.  Plug the 3.5mm stereo mini plug from the 490-95 into the IR RCVR input on the 789-44 Connecting Block 
4.  Plug in the Emitters 3.5mm mono mini plug such as any of the 282, 284, 283 and 286 series into the jacks labeled 

EMITTERS on the 789-44 and affix the opposite end to the IR Sensor Window of the controlled equipment. 

 

283M

 Blink-IR™

Mouse Emitter

To 120 V AC

(unswitched)

781RG

Power Supply

789-44

Connecting Block

283M

 Emitter

283M

 Emitter

Equipment Rack

Hand Held

Remote

VCR

490-95

Micro Link

Plasma-Friendly

IR Receiver

12VDC

+12 VDC

GND
STATUS
IR IN

EMITTERS

IR

RCVR

789-44

CONNECTING BLOCK

®

Satellite Receiver

AV 

Receiver

 

 

Figure 3 - Typical System Layout using 490-95, 789-44, 781RG, and 283M Emitters

 

 
 
 
ADVANCED WIRING CONFIGURATION 

490-95 may also be used where the 7-foot lead is not long enough. In this case, simply use the CB12 Connecting Block 

as a “break-out” block. In 

Figure 4,

 a 490-95 is extended down to a 789-44 Connecting Block and combined with other 

Xantech IR Receivers. 
 

1.  Plug the 3.5mm stereo mini plug from the 490-95 into the IR RCVR input on the CB12 Connecting Block. 
2.  Using 3-Conductor wire (refer to 

Specifications

 section for proper Wire Gauge) connect the terminals labeled 

G S

 of the CB12 to the terminals labeled 

+12VDC, GND, 

and 

IR IN 

on the 789-44 Connecting Block (or other) 

3.  Plug in the 2.1mm Coaxial power plug of the 781RG (or 782) Power Supply (not included) into the jack labeled 

PWR on the 789-44CB. 

CAUTION! 

Do not plug in a 781RG or any other Power Supply into the CB12 when using in a “break-out” 

configuration. This will put 2 supplies in parallel and possibly damage your equipment. If a ‘local’ emitter is needed on 
the CB12, see Step 5 below. 
 
4.  Plug in the Emitters 3.5mm mono mini plug such as any of the 282, 284, 283 and 286 series into the Emitter 

Outputs on the 789-44. 

 