3. If the red Talk-Back LED or the 286M Emitters do not blink when you are sending IR commands

to the 291-00 from a remote control, check the following:

• Make sure the 781RG power supply is plugged securely into a live 120V AC wall outlet.

• Be sure the stereo mini plug of the 291-00 IR Receiver is plugged into the "IR RCVR" jack on the

CB12 Connecting Block, not into the "OUT" jack.

• Check to see that all the mini plugs are properly seated into the mini jacks on the CB12 Connecting

Block.

4. If the 286M Emitters blink, but the component does not respond, reposition the 286M Emitter(s).

They may not be located directly over the component’s infrared receiving "window".  Consult the
owner's manual of the unit or the manufacturer for the exact location of the infrared "window".

5. If the system still does not work, contact the dealer from whom you purchased the 291-10 Hidden

Link, or contact XANTECH Technical Support at 800-843-5465.