Checking Battery Status
When the battery is
ON
, check the indicators to see the battery status.
RED LIGHT
ON
Normal
Normal
RED QUICK
FLASH
Overheated
Temporarily locked. Prohibited from
charging and usage.
RED SLOW
FLASH
Low Temperature
Low temperature triggers charging
protection. Please keep battery
temperature at over 10ºC.
RED DOUBLE
FLASH
Battery Malfunction
Stop using immediately.
Battery Level LED
Status
Battery Level
Battery Use Instructions
• Do not plug or unplug the battery when it is turned on, otherwise the power connector may be
damaged.
• Check the battery firmware for updates before use. The loss caused by the user’s failure to update
the battery firmware in time will be borne by the user.
• The battery should be used between 10℃ and 45℃ (ambient temperature). Overheating (>45℃) may
cause the battery to ignite or explode.
• Do not connect the positive and negative poles of the battery with a wire or other metal objects, to
avoid short circuit.
• Do not immerse the battery in a corrosive liquid. When the battery is placed in clean water for heat
dissipation, please keep the water level between the Max and Min levels. Do not leave the battery in
water for more than 60 minutes. Otherwise, the liquid may flow into the battery and cause damage.
• If there is liquid or foreign matter on the battery terminal, wipe it away as soon as possible and keep
it clean. Otherwise it may cause poor contact, resulting in loss of energy or charging failure.
• Please handle with care during use. Do not disassemble it, puncture its case or manually press the
battery, including but not limited to the following: Sitting on the battery, placing heavy objects on the
battery or otherwise putting pressure on the battery.
• Regularly check the battery terminal, plug and other components before use. Do not use alcohol or
other flammable agents to clean charging devices. Do not use a damaged charging device.
• When charging, place the battery and charging devices on the flat ground that is free of flammable or
combustible materials. Battery charging shall be watched over to prevent accidents.
• For safety, when charging, a distance of more than 30cm shall be kept between two batteries, or
between a battery and a charger, to avoid the malfunction of the charger or the battery, and even
serious consequences such as fire due to overheating.
• Before each operation, make sure the battery has finished charging; never operate with a full load
when the battery is not fully charged.
• It is strictly forbidden to use batteries other than those provided by XAG, or to dismantle or replace a
battery without authorization. For repairs or replacement, please contact XAG or a designated dealer.
• The user shall bear the responsibility for battery accidents, flight failures or other accidents caused by
the use of batteries or components not provided by XAG.
• If a single green light flashes after operation, please charge the battery to 40%-60% capacity before
storage. The battery should be recharged and discharged every 90 days to maintain its activity.
• The battery should be stored in a dry environment at a temperature between 10~30℃ . Do not place
the battery in a location that is too damp or has leakages.
• Do not charge the battery in a damp environment. Product damage caused by liquid immersion due
to reasons other than product quality (such as a damaged battery case) is not covered by the warranty.
• It has been tested under controlled experimental conditions to be resistant to splashes and water.