www.xa.com
26
D. Power System
(1)SmartBattery
① If the battery shows single flashing green after flight, charge it to
40%-60% in time for storage. Batteries not charged timely before
storage could be damaged.
② If the battery is not used for an extended period, charge and
discharge it every three months to keep it active.
③ When the battery is swelling, leaking, deformed, or having exterior
damage, immediately stop using it and contact your local dealer in
a timely manner.
④ Check by sight the exterior of the battery. Should there be any
damage, send it to the maintenance center.
⑤ Do NOT charge the battery in a damp environment.
⑥ Do NOT insert or remove the battery when it is turned on, or its
socket could be damaged.
⑦ Handle the battery with care; NEVER take it apart without
permission.
① If the battery shows single flashing green after flight, charge it to 40%-60% in time for storage.
Batteries not charged timely before storage could be damaged.
② If the battery is not used for an extended period, charge and discharge it every three months to keep
it active.
③ When the battery is swelling, leaking, deformed, or having exterior damage, immediately stop using it
and contact your local dealer in a timely manner.
④ Check by sight the exterior of the battery. Should there be any damage, send it to the maintenance
center.
⑤ Do NOT charge the battery in a damp environment.
⑥ Do NOT insert or remove the battery when it is turned on, or its socket could be damaged.
⑦ Handle the battery with care; NEVER take it apart without permission.
C. RevoSpray System
The spraying system needs to be calibrated once it has a large error (outside of plus or minus 5%) due
to chemical corrosion, thick pesticides, replacement of peristaltic pump parts, etc. Calibration needs to
be done with clean water or pesticides used in operation. In case the health index remains unusual after
calibration, check whether the peristaltic pump tubes or spray tubes are in good condition. Replace
them in time if they shrivel, lose their elasticity or are out of shape.
(1)PeristalticPump
① Take apart the peristaltic pump and check if the peristaltic pump tube and roller are sufficiently
lubricated. If not, apply Vaseline.
② Check if the connectors on the payload control board have come loose or oxidized, etc.
(2)SmartLiquidTank
① Check the sealing ring of the liquid inlet.
② Unscrew the cap and check if the inner tubes are in good condition.
③ Unscrew the filter and clean the dirt off it.
PeristalticPump
SmartLiquidTank