- 6 -
UNIT DIAGRAM - BACK
1
2
3
4
1. Fan
2. 5V/30V Switch
3. AC Input Receptical
4. Fuse
FEATURES / MODES
Voltage Regulation
Briefly press the Voltage (V) knob to select the digit that you want
to adjust, the digit will blink when it is selected. Then turn the
Voltage knob to adjust the voltage to the required setting.
Current/Amperage Regulation
Briefly press the Amperage (A) knob to select the digit that you
want to adjust, the digit will blink when it is selected. Then turn the
Amperage knob to adjust the amps to the required setting.
Adjustable USB Interface
The USB port is also regulated by the voltage and current settings
on the unit. Make sure to set a safe voltage and current/amperage
when using this USB port. To use the USB port, plug in an USB
adapter to the unit and the other end into the device that requires
power.
Constant Voltage (CV) Mode
This is the default mode for the power supply. Once the voltage
and current limits have been set, the device that is being powered
is connected and the power supply is turned on, the unit will
output the voltage limit while varying the amps, the C.V indicator
will be lit. If the unit reaches the amperage limit that is set, it will
automatically switch to constant current (CC) mode.