04
05
NOTE: To turn on XS01-WR, remove the battery insulating fi lm from
the battery compartment. To learn how to turn on diff erent models of
wireless interlinked alarms, please refer to their specifi c user manuals
for more details.
2. Quickly press the test/silence button on one of the 2 units 4 times; it will beep
once and the red LED will fl ash slowly, indicating it has entered pairing mode
and is waiting for a new unit to be added. Quickly press the test/silence button
on the other unit twice; it will beep once and the red LED will fl ash rapidly,
indicating it is searching for a device to connect to.
3. After the search is successful and an interconnected group is created, both
units will beep once and automatically exit the interconnection mode. At
this point, both units will only fl ash once 60 seconds, indicating they are in
normal standby mode.
4. If you want to connect a third alarm to this group, fi rst activate a new
device according to its operating instructions and then quickly press the
test/silence button on either of the 2 previously interconnected units 4
times. This unit will beep once, and the red LED will fl ash slowly, indicating
it is ready to add a new device to the network. Next, quickly press the test/
silence button on the new unit twice, and the red LED will fl ash rapidly as it
searches for a network to connect to. After the third unit successfully joins
the interconnected network, both units will beep once and automatically
exit the interconnection mode.
5. If you want to connect more units, simply repeat step 4. Up to 24 alarms
can be interconnected this way. To ensure that all alarms enter the same
interlinked network, make sure you only work with 2 units at a time one
unit enters the pairing mode and the other unit enters the searching
mode.
6. Test the alarms according to the steps in the section “Alarm Test.”
NOTES
1. The alarm will enter the searching mode or the pairing mode for 60
seconds with the red LED fl ashing. After 60 seconds, repeat step 2 to
connect the alarms. If needed, press the test/silence button once while
the alarm is in the searching mode or the pairing mode, and the red
LED will stop fl ashing and the alarm will quit the pairing mode to enter
normal status.