Indication
• The alarm emits 3 short
beeps.
• The red LED flashes once
per second together with
the beep.
• The initial smoke alarm beeps
continuously while the red LED
is flashing.
• Other interconnected smoke
alarms in the network receive
the signal after 5 seconds and
they will beep continuously
with the red LED flashing.
Release the test/hush button
and all smoke alarms will stop
beeping.
• The testing should be
completed within 3 minutes.
Note!
The test function accurately tests the alarm’s smoke sensing circuit without
the need of test smoke. If your smoke alarm fails to give an audible test signal,
please refer immediately to the troubleshooting guide at the end of this manual.
Never use open flames or flames to test the device.
LED Indicator and Audible Alarm
Status
LED indicator
Audible alarm Operation
Normal
Red LED flashes
once every 60
seconds.
None
Alarm
Red LED flashes
once every
second.
Short quick
beeps
Test
Standalone
smoke device
Red LED flashes
once every
second.
3 loud beeps Push once at the
test/hush button
All
interconnected
units together
Red LED flashes
once every
seconds.
Continuously
alarm until
you release
the test/hush
button
Push once at the
test/hush button
Hush Mode
Red LED flashes
once every 5
seconds.
None
Push the hush
button
Low Battery
Red LED flashes
once every 60
seconds.
1 beep every
60 seconds
Each smoke
alarm gives an
independent
warning.