Page 1: ...X SENSE _ink Wireless Interlinked Combination Smoke and Carbon Monoxide Alarm Type B 10 Year Sealed Battery Operated User Manual Model SCO6 W SCO7 W...
Page 2: ...g into flame Sources of these fires may include cigarettes burning in couches or bedding Carbon monoxide CO is odorless tasteless and invisible it s a silent killer Using electrochemical sensing techn...
Page 3: ...s 100 ppm 10 40 minutes 300 ppm 3 minutes 4 4 37 8 C 40 100 F 10 85 RH non condensi 85 dB at 3 m 10 ft 3 2 0 3 kHz pulsing alarm 9 minutes 868 MHz 24 wireless units only compatible with X Sense wirele...
Page 4: ...ce beyond its temperature range Product Overview A CAUTION THIS COMBINATION SMOKE AND CARBON MONOXIDE ALARM IS DESIGNED FOR INDOOR USE ONLY DO NOT EXPOSE TO RAIN OR MOISTURE DO NOT KNOCK OR DROP THE A...
Page 5: ...ash red This does not indicate that smoke CO is present Silence Mode Smoke Silence Mode Press the test button during an alarm to have the unit enter silence mode for 9 minutes If the smoke concentrati...
Page 6: ...MUST BE DEACTIVATED see Deactivation of the Alarm section AND REPLACED AS SOON AS POSSIBLE If you press the test button when there is low battery the low battery signal will temporarily cease for 10 h...
Page 7: ...e every 5 8 seconds CO Concentration and Symptoms The table below shows the effects of different levels of CO poisoning on the body Parts per Million PPM ite Cy 100 Slight headache nausea fatigue flu...
Page 8: ...Flashes green once None None every 60 seconds Flashes red 3 times 3 long beeps Dangerous smoke every 1 5 seconds every 1 5 concentration is detected seconds Open nearby windows and doors and immediat...
Page 9: ...s once 5 8 seconds unit and has reached the every 5 8 seconds alarm status Please find the initiating unit and take action The LED indicator None Alarm cancellation when flashes green once the smoke c...
Page 10: ...minutes the unit will exit silence mode Flashes yellow once Silence mode during low every 60 seconds None battery After 10 hours the unit will exit silence mode Flashes yellow 3 Silence mode during t...
Page 11: ...hes red 3 times 3 long beeps Dangerous smoke smoke and every 1 5 seconds every 1 5 concentration is initiates an seconds detected Open nearby Ella windows and doors and immediately move to fresh air t...
Page 12: ...concentration is LED flashes once every every 5 8 detected by the 5 8 seconds seconds initiating unit and has reached the alarm status Please find the initiating unit and take action 12UE A CO concent...
Page 13: ...lation flashes green once when the CO every second for 5 concentration level seconds drops below the alarm threshold the alarm signal will stop Then the alarm goes back to the standby mode 2 sets of 3...
Page 14: ...it will exit silence mode eEnd Flashes yellow 3 times None Silence mode during every 60 seconds the end of cycle After 22 hours the unit will exit silence mode Flashes green 3 times None Exiting silen...
Page 15: ...alarms from other manufacturers The X Sense Link wireless interlinked alarms in one multi pack have already been interconnected and the alarms in each multi pack have their own independent interlinked...
Page 16: ...ding to its operating instructions and then quickly press the test silence button on either of the 2 previously interconnected units 4 times This unit will beep once and the LED will flash red slowly...
Page 17: ...n the button until it beeps once more to disconnect After disconnecting it can be reconnected to the same network or added to a new network NOTE The X Sense Link wireless interlinked alarms in one mul...
Page 18: ...interconnected units will sound if the smoke alarm and CO alarm are triggered in the network at the same time the alarm signal of the smoke alarm will take priority over that of the CO alarm 2 This al...
Page 19: ...ill beep continuously with the LED flashing red and green successively Release the test silence button and all the units will stop testing The units testing should be completed within 3 minutes After...
Page 20: ...AILURE TO RESPOND CAN RESULT IN SERIOUS INJURY OR DEATH 2 THE SILENCE FEATURE IS ONLY FOR YOUR CONVENIENCE AND WILL NOT CORRECT A PROBLEM ALWAYS CHECK YOUR HOME FOR A POTENTIAL PROBLEM AFTER ANY ALARM...
Page 21: ...ome with several bedrooms install an alarm in every bedroom If you install only one smoke alarm in your home install the alarm near to all bedrooms where possible and not in a basement or furnace room...
Page 22: ...m _ _____ MINIMUM 7 DEAD AIR 4 BEST Cuts 10cm HERE NEVER HERE MINIMUM 12 30cm MAXIMUM ACCEPTABLE HERE NOTIN NOTIN THISarea THIS AREA ANYWHERE se gn _ ny qe poe 10cm tog x ANYWHERE INTHIS AREA 10 cm IN...
Page 23: ...LARM SHOULD NOT BE USED AS A SUBSTITUTE FOR PROPER INSTALLATION USE AND MAINTENANCE OF FUEL BURNING APPLIANCES INCLUDING APPROPRIATE VENTILATION AND EXHAUST SYSTEMS BEDROOM eee il i FIRE EXTINGUISHERS...
Page 24: ...the wall or ceiling according to the holes of the mounting bracket and drill the screw holes to a depth of 30 mm 1 18 in using a 6 0 mm 1 4 in drill bit Then insert three plastic anchor plugs into th...
Page 25: ...DELIVER 3 BEEPS EVERY 60 SECONDS 3 ONCE THE ALARM IS DEACTIVATED IT WILL NO LONGER FUNCTION IT CANNOT BE REACTIVATED AND MUST BE REPLACED To Deactivate the Alarm Pressing the Test Silence button can s...
Page 26: ...n from fire 7 When household cleaning supplies or similar contaminants are used the area should be ventilated Troubleshooting PROBLEMS SOLUTIONS Check whether the alarm is properly attached to the mou...
Page 27: ...work and the product will not interconnect with times every 60 minutes during the next other units It will still function as a standalone unit 4 days however Environmental Protection Waste electrical...