06
07
THIS SMOKE AND CO ALARM IS DESIGNED FOR INDOOR USE ONLY. DO NOT EXPOSE TO
RAIN OR MOISTURE. DO NOT KNOCK OR DROP THE ALARM. DO NOT OPEN OR TAMPER
WITH THE ALARM AS THIS COULD CAUSE MALFUNCTION.
Test & Silence Button
The Test & Silence button is used to test the unit's electronics and to silence the
unit during an alarm. When testing the alarm weekly, press the test button until
you hear a short beep, indicating that the alarm has entered the test mode.
Note: After a test has begun, the alarm will sound and the red LED will flash. This does
not indicate that smoke/CO is present.
Alarm Sounder
The alarm will sound when there is smoke or CO present, when testing the alarm,
and when there is a fault.
LED Indicator
The LED indicator will flash in conjunction with the alarm sounder. Therefore, it
will flash during the following states: when powering on, in standby mode, during
smoke or CO alarm states, when exiting an alarm state, during test mode, when
there is low battery, in silence mode, when there is a fault and when the unit is at
the end of its life.
Smoke silence time: 9 minutes maximum
CO silence time: 6 minutes maximum
10-year sealed lithium battery
Smoke: Photoelectrical
CO: Electrochemical
About 10 years
Conforms with UL217 & UL2034 standards
0.97 - 1.79%/ft OBS
70 ppm: 60-240 minutes
150 ppm: 10-50 minutes
400 ppm: 4-15 minutes
< 6 µA (average)
< 60 mA (average)
40-100 °F (4.4-37.8 °C)
< 95% (non-condensing)
≥ 85 dB at 9.84 ft (3 m) @ 3.2 ± 0.3 kHz pulsing alarm
Power supply
Sensor type
Product life
Safety standards
Smoke sensitivity
CO sensitivity
Standby current
Alarm current
Operating ambient temperature
Operating relative humidity
Alarm sound
Alarm silence