Recommendations For Surround

 

X-Rite fixtures are designed for color inspection and therefore it is important that precautions be taken to ensure the best 
environment for this purpose. Ambient light (natural or artificial) must be avoided. A room where the X-Rite fixture is used for 
general lighting should be windowless and other lighting should be eliminated. If a windowless room is unavailable, 
light-tight curtains or blinds should be used. If the X-Rite fixtures are used only for lighting of a localized area, then an area 
with little interference from other lighting should be selected or a viewing booth or an enclosing curtain should be used. The 
work surface and surrounding area of view should also be neutral in color. It is typically recommended that Munsell N/7 or 
Munsell N/8 is used. 

Installation Procedure

 

Note:    

Installation should be carried out by a professional carpenter and electrician. 

1.  Remove the fixture from the box. Discard the plastic wrap. 

2.  Remove the cheesecloth bag tied to the center brace. It contains four eyebolts for a chain hung installation. 

3.  Using a flat head screwdriver, remove the four screws securing the reflector to the housing. 

4.  Remove the reflector by flexing it inward to provide clearance on both sides of the housing. Be sure the reflector clears 

the center brace. After the reflector is removed, you now have access to the wires, ballasts, and lamp sockets. 

5.  At each end of the fixture there are two knockouts designed to facilitate installation. Select and remove the appropriate 

knockouts for your specific electrical needs. 

6.  If you are mounting the fixture into a standard grid ceiling, follow the accepted mounting practices for your building code. 

If the fixture is to be chain hung over a work surface, follow "CHAIN HUNG MOUNTING PROCEDURE" on page 4. 

7.  Wire the fixture using the procedure described in "WIRING THE FIXTURE" on page 5. 

8.  Peel off the protective blue film on the reflector. It is only used to protect the reflector during shipment. 

CAUTION 

It is important to remove the protective blue film placed on the reflector for 
shipment purposes. If it is not removed, it may melt and cause permanent 
damage. 

9.  After the fixture has been mounted and properly wired, reposition the reflector and secure it with the screws. 

10.  Insert the lamps. 

Note:    

For fixtures with two different fluorescent source types (PLD-840 dual source and Examolite SD-840B) 

alternate each type as you insert them. 

11.  Verify the unit wiring and lamp placement by selecting each source and observing the lamps illuminated. 

12. 

Examolite TC-440B users only: 

Place a metal cup over one of the the four incandescent lamps. Press the three tabs of 

the metal cup inward to secure it to the lamp. See Figure 1. Repeat this step for the remaining three incandescent 
lamps. 

CAUTION  

Wear protective gloves when performing this operation to avoid finger injuries. 

13. To insert the diffuser, tilt it slightly to provide clearance of the flanges and raise the lens into the housing. Position onto 

the housing flanges. Repeat this step for the second lens. 

Note:   

The lens should always be inserted with its smooth side facing inside of the fixture and the prismatic (textured) 

side facing the outside of the fixture. Orient the lens so that the longest side is parallel to the longest side of the 
luminaire. 

 

Summary of Contents for Examolite TC-440B

Page 1: ...operation KEEP INSTRUCTIONS Retain these instructions for future reference Once you have read these instructions keep them available for other operators to read OBEY ALL WARNINGS Please comply with a...

Page 2: ...ires are designed for 100VAC 50Hz 117VAC 60Hz 220VAC 50Hz 240VAC 50Hz or 277VAC 60Hz operation In all cases proper input power is marked on the box and fixture label CAUTION Do not operate fixture on...

Page 3: ...cific electrical needs 6 If you are mounting the fixture into a standard grid ceiling follow the accepted mounting practices for your building code If the fixture is to be chain hung over a work surfa...

Page 4: ...r Fixture Net Weights Proof lite PLD 4 lamp 57 5 lbs 25 87 kg Prooflite PLD 8 lamp 68 0 lbs 30 6 kg Examolite TC 440B 78 0 lbs 35 1 kg Examolite SD 840B 90 0 lbs 40 5 kg On the rear of the fixture hou...

Page 5: ...PLD 840 Dual Source 2 Sets of 4 Fluorescent 4 Ballasts 2 Inputs Ballast 1 Lamps 1 and 3 Ballast 2 Lamps 2 and 4 Ballast 3 Lamps 5 and 7 Ballast 4 Lamps 6 and 8 Black leads for ballasts 1 and 3 go to...

Page 6: ...is parallel to the longest side of the luminaire Replacement of Lamps Replace lamps at approximately 75 percent of their rated life expectancy to retain spectral characteristics Replace burned out lam...

Page 7: ...incandescent lamps Dimensions Length 48 in 121 19 cm Width 23 75 in 60 3 cm Height 8 in 20 3 cm Weight 78 0 lbs 35 4 kg 90 0 lbs 40 8 kg Power Consumption 368 watts 552 watts Electrical Requirements 1...

Page 8: ...8 incandescent lamps are required for each overhead fixture Lamps are sold in packages of sixteen 16 or as part of a specific lamp kit Examolite SD 840B 5000K Replacement Lamp Kit A LK ESD8450 This k...

Page 9: ...not be liable for errors contained herein or for incidental or consequential damages in connection with the performance or use of this material This manual as well as any revisions are the copyright o...

Page 10: ...7 or 1 616 803 2705 Corporate Headquarters Europe Althardstrasse 70 8105 Regensdorf Switzerland Phone 41 44 842 24 00 Fax 41 44 842 22 22 Corporate Headquarters Asia Room 808 810 Kornhill Metro Tower...

Reviews: