DTP32HS 

Auto Scanning Densitometer 

 

 

Operator’s Manual 

 

 

Summary of Contents for DTP32HS

Page 1: ...DTP32HS Auto Scanning Densitometer Operator s Manual...

Page 2: ......

Page 3: ...ets all requirements of the Canadian Interference Causing Equipment Regulations Cet appareil num rique de la classe B respecte toutes les exigences du R glement sur le mat riel brouilleur du Canada Eq...

Page 4: ...nstrument This agreement shall be interpreted in accordance with the laws of the State of Michigan and jurisdiction and venue shall lie with the courts of Michigan as selected by X Rite Incorporated T...

Page 5: ...ip Reading Densitometer reflection versions it will by default report itself as a DTP32R Most existing software packages will reference a DTP32R in their connection menu while newer software may use D...

Page 6: ...onnect the interface cable as shown CAUTION Use only the 100 240VAC input 12VDC output Switching Power Supply to power the instrument 3 Plug the small end of the switching power supply into the power...

Page 7: ...omplete list of conditions reported by the LED Operation Mode Solid Green self test passed and instrument is ready for use with defined strip Slow Flashing Green strip reading in progress strip being...

Page 8: ...75 19mm to the left of the alignment mark optical path when measuring This ensures the read switch is activated when the strip is inserted into the instrument TOP VIEW 0 75 19mm min 4 101 6mm max to...

Page 9: ...any time All that is required is that you insert the reflection reference into the instrument as you would with any other strip 1 Center the designated end of the reflection reference under the alignm...

Page 10: ...re read is required on the pass The instrument s LED will stay at solid green after all passes are successfully read Strip Positioning and Measurement Techniques The following information is provided...

Page 11: ...perly which could happen if power was removed during reprogramming Try reprogramming the instrument again refer to the programming instructions that came with your update Densitometer and software not...

Page 12: ...nce to achieve years of reliable operation However to protect your investment and maintain reading accuracy a few simple cleaning procedures should be performed from time to time General Cleaning When...

Page 13: ...erence can be cleaned with a lint free cloth whenever required Make sure to return the reference to its protective case when finished Always handle the calibration reference by the edges If required a...

Page 14: ...y flat spots if the instrument sits idle for and extended period of time These flat spots could cause the first few moments of a reading to contain unwanted noise To prevent this condition the instrum...

Page 15: ...10 16 mm min in direction of travel by 0 5 13 mm min wide 1 mm wide 1 0D contrast space between patches or 0 5D min difference between patches Communication Interface Protocol as described in X Rite D...

Page 16: ...s Laboratories UL 61010 1 Canadian Standards Association CSA 22 2 No 1010 1 92 CENELEC IEC EN 61010 1 Design and specifications subject to change without notice Standard Accessories Calibration Refere...

Page 17: ...rip guide Insert strip at X The DTP32R has a strip guide mechanism that ranged numerically from 5 to 30 Some software packages indicate a setting for this guide These prompts can be ignored with the D...

Page 18: ...ame as any normal scan Once the unit has recognized the initial barcode as being part of a set up barcode the LEDs will slowly flash between amber and green This same flash pattern will continue while...

Page 19: ...Baud Rate Configuration First scan this bar code and then scan 1200 2400 4800 9600 or 19200 baud rate codes on the following five pages for the desired setting...

Page 20: ...Baud Rate 1200...

Page 21: ...Baud Rate 2400...

Page 22: ...Baud Rate 4800...

Page 23: ...Baud Rate 9600...

Page 24: ...Baud Rate 19200...

Page 25: ...Auto Transmit Configuration First scan this bar code and then scan the On or Off code on the following two pages for the desired setting...

Page 26: ...Auto Transmit On...

Page 27: ...Auto Transmit Off...

Page 28: ...Decimal Point Configuration First scan this bar code and then scan the On or Off code on the following two pages for the desired setting...

Page 29: ...Decimal Point On...

Page 30: ...Decimal Point Off...

Page 31: ...Times Ten Configuration First scan this bar code and then scan the On or Off code on the following two pages for the desired setting...

Page 32: ...Times Ten On...

Page 33: ...Times Ten Off...

Page 34: ...Data After Pass Configuration First scan this bar code and then scan the On or Off code on the following two pages for the desired setting...

Page 35: ...Data After Pass On...

Page 36: ...Data After Pass Off...

Page 37: ...Delimiter Configuration First scan this bar code and then scan the Carriage Return or Carriage Return and Line Feed code on the following two pages for the desired setting...

Page 38: ...Delimiter CR...

Page 39: ...Delimiter CR LF...

Page 40: ...Separator Configuration First scan this bar code and then scan the Space Comma Tab Carriage Return or Carriage Return and Line Feed code on the following five pages for the desired setting...

Page 41: ...Separator Space...

Page 42: ...Separator Comma...

Page 43: ...Separator Tab...

Page 44: ...Separator CR...

Page 45: ...Separator CR LF...

Page 46: ...Min Max Configuration First scan this bar code and then scan the Off Min Max or Min and Max code on the following four pages for the desired setting...

Page 47: ...Min Max Off...

Page 48: ...Min Max Min...

Page 49: ...Min Max Max...

Page 50: ...Min Max Min Max...

Page 51: ......