background image

 

 INSTALLATION INSTRUCTIONS  

(1) Connect the camera to a monitor with 75ohm type coaxial cable. 
(2) Connect the power cord to DC 12V power supply. 
(3) Fix camera to the ceiling or wall by mounting device. 

 

 

  ADJUSTING THE CAMERA ZOOM AND FOCUS   

1.

 

Loose the zoom ring screw. 

2.

 

Turn the zoom ring to the desired zoom condition. 

3.

 

Tight the zoom ring screw. 

4.

 

Loose the focus ring screw. 

5.

 

Turn the focus ring to focus. 

6.

 

Tight the focus ring screw. 

7.

 

Check the result with tools. 

 

 

 SPECIFICATIONS  

Model Type

 

XD445MR 

Image Pick-up Device

 

SONY 1/3” CCD High Resolution 

Effective Picture Elements

 

NTSC: 768*494, PAL: 752*582 (H*V)

 

Horizontal Resolution 

520 TV lines

 

Minimum Illumination

 

0 LUX @ IR

 

S/N Ratio

 

More than 48 dB

 

Gamma Characteristic

 

0.45

   

Gain Control

 

Automatically

 

White Balance

 

ATW (2500°K ~ 9,500°K)

 

Lens Furnished

 

3.7-12mm / F1.4 

Auto Iris Control

 

DC-Drive Auto Iris lens

 

Auto Electronic Shutter

 

NTSC: 1/60s~1/100,000s, PAL: 1/50s~1/110,000s

 

Video Output

 

1 Vp-p Composite Video / 75 ohm BNC connector

 

Power Supply

 

DC 12V / 280 mA

 

Operating Temp.

 

-10°C to 50°C (14°F to 122°F)

 

Water Resistance

 

IP66

 

IR-LED

 

11 units of high efficiency 850nm IR-LED

   

IR Project Distance

 

25 Meters

 

Dimensions

 

142mm (

Φ

) * 115.5mm (H)

 

 
 