background image

Copyright © 2021 WyreStorm Technologies | 

WyreStorm.com

 

SW-540-TX-W User Manual | 210908 

4 of 12 

Technical Support: 844.280.WYRE (9973) 

[email protected] 

 

USB Behavior & Performance 

The SW-540-TX-W features 3 x USB host ports. Two ports are USB-B 2.0 connections and the third utilizes the USB-C 
port. By default, the switcher is configured to auto-switch the active USB host based on the selected video input 
port.  

USB-B Host 1 is tied to the VGA and HDMI 1 inputs and USB-B Host 2 is tied to HDMI 2.  

For example, if the active video input on the switch is HDMI 1 the active USB host port will be USB-B 1. If the active 
video input is the USB-C connection, then the USB-C connection becomes the active host port.  

This auto-switch behavior can be manipulated via the web interface of the switcher. If you do not want the USB host 
to follow an active video input, you can uncheck the Auto check box and manually choose which host port will 
always be active. 

 

The 3 x USB device ports integrated into the switcher support full USB 2.0 data speeds. The SW-540-TX-W is 
equipped with HDBaseT spec 2.0 and can transmit USB over the Category output to a compatible receiver (RX-500 
recommended). In this scenario, due to limitations with HDBaseT, USB 2.0 bandwidth is restricted to 190Mbps vs 
the full 480Mbps. Keep this limitation in mind when connecting isochronous devices such as webcams over 
HDBaseT. WyreStorm has tested our own FOCUS webcams and CAM-200-PTZ to work with the SW-540-TX-W over 
HDBaseT. WyreStorm cannot guarantee performance or compatibility of 3

rd

-party webcams. 

 

Security 

Security protocols are implemented on the SW-540-TX-

W including HTTPS for secure access to the switcher’s web 

interface and TLS for accessing the API. 

HTTPS is enabled by default but can be disabled if required. TLS is disabled by default and the switcher uses a 
standard Telnet connection to access the API. If a secure connection to the API is required, TLS can be enabled. The 
TLS connection allows you to change the default password to a custom value. Keep in mind that WyreStorm drivers 
will use default credentials. It is recommended to keep the default credentials unless you are writing a custom driver 
for the switcher. 

Connection information and API commands can be found in the SW-540-TX-

W’s API document available at 

wyrestorm.com. 

Summary of Contents for SW-540-TX-W

Page 1: ...SW 540 TX W User Manual v1 0...

Page 2: ...08 2 of 12 Technical Support 844 280 WYRE 9973 Support WyreStorm com Contents Contents 2 Connections 3 USB Behavior Performance 4 Security 4 Multiview 5 Input Switching Modes 6 Wireless Access Point C...

Page 3: ...rial signal to transmit over an HDBaseT link to control a peripheral device such as a display or projector The RS232 Control port allows serial control of the switcher via API commands Wi Fi Antennas...

Page 4: ...ipped with HDBaseT spec 2 0 and can transmit USB over the Category output to a compatible receiver RX 500 recommended In this scenario due to limitations with HDBaseT USB 2 0 bandwidth is restricted t...

Page 5: ...le if two laptops are connected via HDMI 1 and HDMI 2 the switcher will automatically build a split screen layout If four devices are connected the screen will be split into quadrants Examples are sho...

Page 6: ...input When the switch is in multiview mode you will be able to select or de select multiple inputs for the Primary output output 1 The Primary and Secondary outputs are mirrored in this mode Full Scr...

Page 7: ...be able to wirelessly cast content They will not have internet access AP Disabled This mode completely disables the built in AP This mode should be used when you plan to use an existing network s acc...

Page 8: ...is adjustable for both the 2 4 and 5Ghz bands WyreStorm recommends leaving this set on the default values Only change a wireless channel if severe interference is occurring or connection problems aris...

Page 9: ...output timing based on a display s EDID However if you experience compatibility problems you can choose to force a resolution and refresh rate Also by forcing an output timing you may experience sligh...

Page 10: ...80 WYRE 9973 Support WyreStorm com Adjusting EDID Each input allows for manual assignment of an EDID If you experience compatibility problems with a device you can adjust the EDID for the input port r...

Page 11: ...standby commands These values will work with most major display manufacturers If you experience issues with one or both of these default commands not working you can enter a custom HEX value for both...

Page 12: ...ng the switcher will wait before sending the power off command Enter in a value of 0 to disable auto standby You can also choose what type of command is sent CEC RS232 or Both during auto sync detecti...