Setup and Configuration

 IMPORTANT! Installation Guidelines

•  Do not connect the power supply or power on the PoE switch until all NetworkHD devices are connected to the network switch.
•  NetworkHD uses AutoIP to assign IP addresses in the range of 169.254.x.x out of the box. Set the PC being used for configuration to an address in this range 

prior to starting the configuration process.

•  In order for NetworkHD encoders and decoders to be controlled by the NHD-000-CTL, the AV port on the CTL MUST be connected to the same LAN/VLAN as 

the NHD encoders and decoders. 

•  In order for the devices in the system to be controlled via a 3rd party controller, the CONTROL port MUST be connected to the same LAN/VLAN as the control 

system.

•  The NHD-000-CTL’s two Ethernet ports are designed to be used in different Networks or VLANs. When using a single Network or VLAN for example when 

using NetworkHD Touch – do not connect both ports – only use the AV port of the CTL.

Installation and Connections

1. 

Install NHD devices to allow airflow through the product, for encoders it is recommended to use the NHD-000-RACK. The install location should be dry, 
well ventilated, and out of direct sunlight.

2. 

Connect sources to the NetworkHD encoders using an HDMI cable from a quality brand such as 

WyreStorm Express 

ensuring a firm port connection.

3. 

Connect the HDMI display to the NetworkHD decoders using an HDMI cable from a quality brand such as 

WyreStorm Express

 ensuring a firm port 

connection.

4. 

Connect NetworkHD encoders, decoders, and CTL to the network switch using well terminated and tested category cable of no more than 100m/328ft.

5. 

Connect the decoders RS-232 port to the display following the pinout in the 

RS-232 Wiring

 section.

6. 

Connect the Audio Out to an amplifier with analog audio in following the pinout in the 

Audio Wiring

 section.

 Download the 

NetworkHD Switch Mapping Worksheet

 from any NetworkHD product page to keep track of Mac addresses, device and alias names for later 

reference. This will aid in any reconfiguration or troubleshooting.

NetworkHD 000 Series Console Configuration

In addition to the steps below more information on configuration can be found in the 

NetworkHD 100-200-400 Series Installation Guide

.

1. Connect a PC to the same LAN/VLAN as the NetworkHD components and ensure it is within the same subnet/IP range as the components default 

169.254.x.x IP addresses. The NHD-000-CTL is set to a static address of 169.254.1.1 by default – do not choose this address for your PC.

2. Power 

On

 the NHD devices by connecting the included power supplies to the 

Power Input 

or by powering 

On

 the PoE switch.

3. Open the WyreStorm Management Suite (Available from the 

WyreStorm

 website) and launch the 

NetworkHD 000 Series Console

 and press 

Search

.

Note:

 If a no devices are discovered, verify that the CTL and PC are on the same LAN/VLAN and that the IP address of the PC is within the same subnet/IP 

range as the CTLs default 192.168.11.243 IP address and disable or create an exception for the 

NetworkHD Console

 in the 

Windows Firewall

.

4. Configure the system as per the instructions in the User Reference Guide (Available from the NHD-100-TX/RX Product Pages.) Right Click on the NHD-100-

TX/RX to see its available options, including setting the devices IP address and setting an Alias name. You will also find other configuration options under the 

Batch Settings

 window. 

Note: 

If a 3rd Party control system with a WyreStorm driver for NetworkHD is going to be used, the encoders must use the names Input1, Input2, etc.  This also 

applies to decoders, Output1, Output2, etc.
5. Upload to the configuration to the NHD-000-CTL by right clicking the CTL in the 

Other Devices

 section and selecting Upload.

6. Configure the scaling, HDCP values of each decoder based on the requirements of the content and display using the 

H.264

 settings found in the Video tab in 

the 

Batch Settings

 screen.

Using NetworkHD

NetworkHD Touch

1. For fast and easy switching of encoders to decoders download and 

install NetworkHD Touch on an iPad from the 

App Store

. This award 

winning app provide one touch operation to send the output of a source 
to a display or video wall and does not require an external control 
system.

2. Refer to the 

NetworkHD Touch Installation Guide

 for configuration 

located on 

wyrestorm.com

 for operation once installed.

Enado or 3rd Party Control Systems

1. In addition to NetworkHD Touch for one touch switching an Enado or 3rd 

party control system expands the capability of the system by providing 
control of sources for changing channels or switching inputs. Control of 
sources using an Enado is easily accessible right from the NetworkHD 
Touch app.

2. Enado templates are downloadable from within the configuration and 

3rd party drivers for popular control system are available on 

wyrestorm.

com.

Copyright © 2017 WyreStorm Technologies | 

wyrestorm.com

NHD-210-RX v2 Quickstart Guide | 170630

UK: +44 (0) 1793 230 343 | ROW: 844.280.WYRE (9973) 

[email protected]

3 of 4

Summary of Contents for NetworkHD 200 series

Page 1: ...e of switches listed in the NetworkHD Switch Recommendation Guide These switches have been verified by WyreStorm to meet the requirements of a NetworkHD system NetworkHD requires a Layer 2 managed switch network with support for Multicast IGMP snooping enabled Ensure that the switch being used supports these features and that they are configured prior to connecting the NetworkHD system Configure a...

Page 2: ...esolution While Cat5e can be used WyreStorm recommends using Cat6 or higher to ensure the highest content performance available See Video Resolutions in the Specifications table before determining cable type and length HDMI DVI Wiring WyreStorm recommends using pre terminated HDMI and DVI cables due to the complexity of these connector types Using pre terminated cables will ensure that these conne...

Page 3: ...esses The NHD 000 CTL is set to a static address of 169 254 1 1 by default do not choose this address for your PC 2 Power On the NHD devices by connecting the included power supplies to the Power Input or by powering On the PoE switch 3 Open the WyreStorm Management Suite Available from the WyreStorm website and launch the NetworkHD 000 Series Console and press Search Note If a no devices are disc...

Page 4: ...DMI HDMI HDCP 1 4 Ethernet 1x 8 pin RJ 45 female 10 100Base T PoE RS 232 1x RS 232 3 pin Phoenix Copyright 2017 WyreStorm Technologies wyrestorm com NHD 210 RX v2 Quickstart Guide 170630 UK 44 0 1793 230 343 ROW 844 280 WYRE 9973 support wyrestorm com 4 of 4 Troubleshooting Verify that all NHD devices contain the latest version of firmware This will ensure that all devices are up to date and worki...

Reviews: