background image

6

Technical Support: [email protected] US: +1 866 677 0053 EU: +44 (0) 1793 230 343

REAR P

ANEL DESCRIPTION

7.     Rear Panel Description

1

Mirrored HDMI OUT ports 1~8 (From left to right) - 

Mirrored to HDBaseT output, connects to the local HDMI 

devices with HDMI or DVI to HDMI cables.

NOTE:  this port supports up to 1080p resolution only.  

A 4K source cannot be duplicated

2

HDBaseT OUT ports 1~8 (From left to right) - Connects to 

HDBT IN ports of compatible HDBaseT Receivers (such 

as RX-70-4K) with single Cat5e/6 cable for transmission 

of HDMI Audio/Video, IR, RS232, Ethernet and 100W 

power.

NOTE: HDMI OUT has higher priority over HDBT OUT 

if both are connected.

3

HDMI IN ports 1~8 (left to right) - Connects to the local 

HDMI source devices with HDMI cables or DVI to HDMI 

cables.

4

IR RX Receiver ports 1~8 (left to right) - Connects to the 

supplied broadband IR receivers for IR signal reception to 

control the IR devices remotely from the matrix side.

5

Ethernet port - Connects to an active IP network to share 

network access with any of the eight Ethernet equipped 

devices at the HDBaseT end.

6

RS485 port - Connects to a RS485 device, such as a PC 

or control system device, with a RJ45 to RS485 converter 

and a serial cable for matrix control.

7

LAN port - Connects to an active IP network for control 

of matrix via LAN (Telnet & Web GUI).

8

RS232 port - Connect to a RS232 device, such as a 

PC or control system device, with the supplied USB to 

UART cable or a direct serial cable for matrix control or 

firmware upgrading.

9

IR Ext. port - Connects to a supplied IR receiver (not 

broadband cable) for IR signal reception to locally control 

the matrix.

10

EDID DIP switch - Manual DIP setting for EDID 

management for improved device connection 

compatibility. (See EDID section for settings)

11

EDID DIP switch default setting diagram - Default factory 

setting reference

13

Firmware Upgrade DIP switches - DIP settings to update 

transmission card firmware.

14

IR TX ports 1~8 - Connects to the supplied IR emitters 

for IR signal transmission to control the IR devices 

remotely from the sink side.

15

Power switch - Powers matrix on/off

16

Fuse - To prevent voltage/current excess that can 

damage circuitry. Lift cover to replace fuse

17

Power - AC 100~240V 50/60Hz power input.

18

GND - Electrical grounding to prevent static build up

12

Update mode switch

• 

Left position for Normal mode (default) – Normal 

matrix function including RS232 control. 

Note: Matrix software cannot be updated in this 

setting.

• 

Right position for Update mode – normal matrix 

function without RS232 control functionality.  RS232 

required for firmware update.

Note:  Ensure switch is returned to the left 

‘Normal’ mode after updating for full RS232 control 

functionality.

RS232 cable required for firmware update.

2
3

5

6 7

8

9

10

11

12 13

14

15

16

17 18

4

1

Summary of Contents for MX-0808-PP-pOH-4K

Page 1: ...tion Manual WyreStorm 4K Matrix Solutions MX 0808 PP pOH 4K 4K HDBaseT 5 Play 8x8 Matrix including PoH Bidirectional IR and RS232 Serial Control Thank you for choosing this WyreStorm product Please re...

Page 2: ...full compatibility with leading third party control systems including the WyreStorm Enado multi platform browser based control interface Seeking to avoid compatibility issues encountered by some manu...

Page 3: ...single Cat5e 6 7 UTP cable to each display point for ease of installation Conforms to IEEE 568B standards Each HDMI port also supports DVI signals Each Output port can be fed to multiple displays cas...

Page 4: ...Switch 1 x Ethernet 1 x LAN 1 x RS232 1 x RS485 Output Bandwidth Signaling Rate 6 75Gbps Input video Signal 0 5 1 0 volts p p Input DDC Signal 5 volts p p TTL Maximum Pixel Clock 297MHz Video Impeden...

Page 5: ...will not be made unless Enter is pressed Cable Type Range Supported Video Cat5e 6 100m 328ft 1080p 60Hz 36bit Deep Colour 70m 230ft 1080p 60Hz 48bit Deep Colour 1080p 60Hz 3D 4Kx2K 30Hz 4 2 2 chroma s...

Page 6: ...matrix via LAN Telnet Web GUI 8 RS232 port Connect to a RS232 device such as a PC or control system device with the supplied USB to UART cable or a direct serial cable for matrix control or firmware...

Page 7: ...r IRRX Receiver HDMI UTP Cat5e 6 7 Control System Additional control via RS232 LAN RS485 08 IR RX receiver and IR TX emitter placed discretely on the display with a clear line of sight to the remote h...

Page 8: ...tional and should be used only if there is insufficient power from the transmission device Power is passed along the Cat5e 6 7 cable so the quality of termination cable and condition are essential for...

Page 9: ...caled down to compatible stereo PCM for those that cannot without sacrificing the integrity of the distribution Visit wyrestorm com for more information on 4K HD scaling and Dolby downmixing The matri...

Page 10: ...ched to an alternative matrix control mode Remote Control at the Display End Remote IR When controlling the matrix remotely from the display side the matrix automatically detects which particular outp...

Page 11: ...between the input sources connected to the matrix for each individual output display So for example using the previous next buttons for 1 allows you to select the source to be set to display 1 manu al...

Page 12: ...ctions Options in the Message R eceive window include Press to view the current condition of all output ports Press to delete the previous received message iii Send Message Window In the Send Message...

Page 13: ...n a COM Port is connected the only option will be to Disconnect and vice versa Note In Connect Status area Connected indicates that the matrix is connected to the COM port and communication is enabled...

Page 14: ...t successfully by using Netfinder Logging in to matrix control screen or Telnet sections for further details EDID Settings The EDID SET window allows users to access and configure EDID settings that c...

Page 15: ...The IR Matrix allows the creation of different IR paths to remotely control the IR devices such as source or display devices using each device remote control from the matrix location 1 2 3 4 1 UTP Lon...

Page 16: ...le to distin guish wher e the remo te hand set is being used to chang e INPU TS and OUTP UTS and is able to switc h accor dingly depe nding on the user s locati on As such the funct ion of the hand se...

Page 17: ...ransmit serial data to PC Baud rate 9600bps Data bits 8bits Parity None Stop bits 1 Flow control None Com Port Setting COM CTL After fully connecting all inputs and outputs to the matrix and installin...

Page 18: ...t 1 Intput 2 Intput 3 Intput 4 Intput 5 Intput 6 Intput 7 Intput 8 03 EDID Set MX0808 PP 1 2 17 Technical Support support wyrestorm com US 866 677 0053 EU 44 0 1793 230 343 source for Output 4 MX0606...

Page 19: ...ce remote handsets IR emitters must be firmly connected to correct ports of matrix and securely attached directly over device IR sensor windows All IR cables should be free of bends kinks tangles knot...

Page 20: ...s likely that you will not need to change the setting HINT If your remote control is not working before changing the battery try changing the System Code on the handset in case it has accidentally bee...

Page 21: ...both request and send the required information For example a display will communicate 1080p capability with 2ch audio which the source device will accept and output the correct format for the display...

Page 22: ...ignal bandwidth is attempted using insufficient cable Should you encounter any technical difficulties when installing and configuring the matrix we are confident solutions can be found by working thro...

Page 23: ...or swapping the outputs of the matrix switch used If the problem remains on the same screen this may be caused by a connection problem between matrix and display turn off all equipment and swap the si...

Page 24: ...ents included with your purchase or check compatibility of third party control systems with your WyreStorm dealer 6 IR dropout issues these can be due to exterior influences emitting infrared radiatio...

Page 25: ...SPEED or category 2 HDMI cables that have been tested to perform at speeds of 340Mhz or up to 10 2Gbps which is the highest bandwidth currently utilised over an HDMI cable and can successfully handle...

Page 26: ...d unless such information is provided Should you feel your product does not function adequately due to defects in materials or workmanship we referred to as the warrantor will for the length of the pe...

Page 27: ...over HDBT TMDS Transition Minimized Differential Signal TV Television UART Universal Asynchronous Receiver Transmitter GLOSSARY 2 There are no express warranties except as listed under limited warran...

Page 28: ...Reference Log Input Reference Log 27 Technical Support support wyrestorm com US 866 677 0053 EU 44 0 1793 230 343 INPUT REFERENCE LOG INPUT Input number on Matrix Source Location Source Details Sourc...

Page 29: ...Reference Log 28 Technical Support support wyrestorm com US 866 677 0053 EU 44 0 1793 230 343 OUTPUT REFERENCE LOG OUTPUT Output number on Matrix Output Location Display Details Display Resolution Aud...

Page 30: ...30 Technical Support support wyrestorm com US 1 866 677 0053 EU 44 0 1793 230 343 INSTALLATION NOTES 22 Installation Notes...

Page 31: ...31 Technical Support support wyrestorm com US 1 866 677 0053 EU 44 0 1793 230 343 INSTALLATION NOTES...

Page 32: ...ms Parkway Suite 104 Memphis TN 38133 Tel 901 384 3575 Fax 901 384 3574 Unit 22 Ergo Business Park Swindon Wiltshire SN3 3JW UK Tel 44 0 1793 230 343 Fax 44 0 1793 230 583 WyreStorm Technical Support...

Reviews: