background image

 

The   lightning   flash   with   arrowhead   symbol   within   an   equilateral   triangle   is   intended   to   alert   the   user   to   the 
presence   of   uninsulated   “dangerous   voltage”   within   the   product's   enclosure   that   may   be   of   sufficient 
magnitude   to   constitute   a   risk   of   electric   shock. 

No   naked   flame   sources,   such   as   lighted   candles,   should 
be   placed   on   the   apparatus. 

WARNING:   The   terminals   marked   with   symbol   of   “+/-“ 
may   be   of   sufficient   magnitude   to   constitute   a   risk   of 
electric   shock.   The   external   wiring   connected   to   the 
terminals   requires   installation   by   an   instructed   person   or   the   use   of   ready   made   insulated 
leads   or   cords. 

Correct   Disposal   of   this   product.   This   marking   indicates   that   this   product   should   not   be 
disposed   with   other   household   wastes   throughout   the   EU.   To   prevent   possible   harm   to   the 
environment   or   human   health   from   uncontrolled   waste   disposal,   recycle   it   responsibly   to 
promote   the   sustainable   reuse   of   material   resources.   To   return   your   used   device,   please   use   the   return   and 
collection   systems   or   contact   the   retailer   where   the   product   was   purchased.   They   can   take   this   product   for 
environmentally   safe   recycling. 

Keep   your   packaging!   It   is   custom   made   for   your   unit   and   will   effectively   protect   it   for   possible   future   use. 

Be   sure   to   register   your   product.   It   is   very   important   to   complete   the   warranty   registration   form   located   on 
our   website.   Complete   and   submit   the   form   within   30   days   of   purchase   to   activate   your   warranty.   

 

 

FCC   Warning 
This   equipment   has   been   tested   and   found   to   comply   with   the   limits   for   a   Class   B   digital   device,   pursuant   to   Part   15   of 
the   FCC   Rules.   These   limits   are   designed   to   provide   reasonable   protection   against   harmful   interference   in   a   residential 
installation. 
 
This   equipment   generates,   uses   and   can   radiate   radio   frequency   energy   and,   if   not   installed   and   used   in   accordance 
with   the   instructions,   may   cause   harmful   interference   to   radio   communications.   However,   there   is   no   guarantee   that 
interference   will   not   occur   in   a   particular   installation.   If   this   equipment   does   cause   harmful   interference   to   radio   or 
television   reception,   which   can   be   determined   by   turning   the   equipment   off   and   on,   the   user   is   encouraged   to   try   to 
correct   the   interference   by   one   or   more   of   the   following   measures: 

Reorient   or   relocate   the   receiving   antenna. 

Increase   the   separation   between   the   equipment   and   receiver. 

Connect   the   equipment   into   an   outlet   on   a   circuit   different   from   that   to   which   the   receiver   is   connected. 

Consult   the   dealer   or   an   experienced   radio/TV   technician   for   help. 

 
Caution:   Any   changes   or   modifications   to   this   device   not   explicitly   approved   by   manufacturer   could   void   your 
authority   to   operate   this   equipment. 
 
This   device   complies   with   part   15   of   the   FCC   Rules.   Operation   is   subject   to   the   following   two   conditions:   (1)   This 
device   may   not   cause   harmful   interference,   and   (2)   this   device   must   accept   any   interference   received,   including 
interference   that   may   cause   undesired   operation. 
 
The   device   has   been   evaluated   to   meet   general   RF   exposure   requirement.   The   device   can   be   used   in   portable 
exposure   condition   without   restriction. 

 

©   Wyred   4   Sound.   All   rights   reserved.  

STI-v2   Manual   v1

 

 

Summary of Contents for STI-1000 v2

Page 1: ...STI v2 Series STI 500 v2 STI 1000 v2 STEREO INTEGRATED AMPLIFIER USER MANUAL ...

Page 2: ...igger Cable Remote Control AAA Batteries 2 STI 500 v2 or STI 1000 v2 Stereo Integrated Amplifier We strongly suggest keeping the original packaging in case of the need to ship your STI v2 in the future Wyred 4 Sound All rights reserved STI v2 Manual v1 2 ...

Page 3: ...or pinched particularly at the plugs convenience receptacles and at the point where they exit from the apparatus Unplug this apparatus during lightning storms or when unused for long periods of time Refer all servicing to qualified personnel Servicing is required when the apparatus has been damaged in any way such as the power cord or plug is damaged Other damage may occur if liquid or objects have...

Page 4: ...s been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference ...

Page 5: ...tion 6 Setup Menu Instructions 7 Powering Your STI v2 7 DC Trigger 7 Getting Connected 8 Break in Period 8 Troubleshooting 8 9 Got Hum 9 Amplifier Faults 9 Warranty Coverage 10 11 Service 11 Specifications 12 Your Notes 13 Wyred 4 Sound All rights reserved STI v2 Manual v1 5 ...

Page 6: ...the VFD display and optical rotary encoder Allowing input naming and HT Bypass input selection the setup menu is easily accessed for customization Several display dimming steps including off are available through the remote Powering up the STI v2 can be done by pushing in on the volume knob by pressing power on the remote and by the remote DC trigger in when HT Bypass is selecting in the setup men...

Page 7: ...ure you have all connections made properly to ensure no damage is made to your equipment Powering Your STI v2 When power is applied to the STI v2 and the switch located on the rear is in the on position the STI v2 will turn on If you would like to manually turn the amplifier on and off this switch is where you would want to do so Leaving your amplifier on all the time will not hurt it shorten the li...

Page 8: ...nect cables would be a great way to ensure your system is closer to what we call our reference We offer superior cables at an affordable price For more information please visit our website or send an email to support wyred4sound com Break in Period Your new STI v2 series amplifier will deliver outstanding performance right out of the box However you should plan on improvements as it reaches its nor...

Page 9: ...nected try putting a cheater plug ground isolator on one or all components in order to eliminate a ground loop issue NOTE We only recommend using a ground isolator for troubleshooting purposes and should be removed after the problem has been found Having the ground of any unit disconnected can potentially create a dangerous situation An easy way to locate a noisy component is to replicate the prob...

Page 10: ... with non Wyred 4 Sound products b to damage caused by accident abuse misuse flood fire earthquake or other external causes c to damage caused by operating the product outside the permitted or intended uses described by Wyred 4 Sound d to damage caused by service including upgrades and expansions performed by anyone who is not a representative of Wyred 4 Sound or a Wyred 4 Sound Authorized Service P...

Page 11: ...ipped to the factory will be refused and returned freight collect if not accompanied by a Wyred 4 Sound Service Department issued return authorization number RA Number Wyred 4 Sound Phone 1 805 466 9973 Fax 1 805 462 8962 Email support wyred4sound com Website wyred4sound com Office hours Mon Thurs 7am 4 30pm Fri 7am 11am PST Service procedure 1 Contact your dealer or Wyred 4 Sound to discuss the is...

Page 12: ...0 1db 0 15db Lower Bandwidth 1 5Hz all loads 1 5Hz all loads Dynamic Range A wt 111db 108db Gain 42db 42db Sensitivity 0 55V 0 75V Output Impedance 0 005Ω 0 005Ω Output Impedance Pre Out 100Ω 100Ω Balanced Input Impedance 60 4Ωk 60 4Ωk Unbalanced Input Impedance 60 4Ωk 60 4Ωk Min Load 3Ω 4Ω Dampening Factor 100Hz 8Ω 2000 2000 Max Output Current 35A 40A Channel Tracking 0 050db 0 050db Crosstalk 20...

Page 13: ...Your Notes Wyred 4 Sound All rights reserved STI v2 Manual v1 13 ...

Page 14: ...ail support wyred4sound com Be sure to sign up for our newsletter to receive the latest news and updates See the Wyred In section in the footer of our website Follow us on Facebook facebook com wyred4sound Follow us on Twitter twitter com Wyred4Sound Wyred 4 Sound All rights reserved STI v2 Manual v1 14 ...

Reviews: