Instruction Manual

Thank you for choosing this Wyrestorm product.

Please read these instructions carefully before installing to avoid complications later.

Wyrestorm Extender Set 

Solutions

Part Number

     EX-1UTP-IR-100-EDID 

Part Number

     EX-1UTP-IR-100-POH

HDMI® Extension over Cat5e/6/7 with Full HDBaseT™ 

up to 100m incl. bidirectional IR control, RS232 1:2 

HDMI splitting capabilities, EDID management and 

Power-over-HDBaseT

*

Summary of Contents for EX-1UTP-IR-100-EDID

Page 1: ...lease read these instructions carefully before installing to avoid complications later Wyrestorm Extender Set Solutions Part Number EX 1UTP IR 100 EDID Part Number EX 1UTP IR 100 POH HDMI Extension over Cat5e 6 7 with Full HDBaseT up to 100m incl bidirectional IR control RS232 1 2 HDMI splitting capabilities EDID management and Power over HDBaseT ...

Page 2: ...ble true 5 play convergence for distribution of video audio control Ethernet and Power through a single Cat5e 6 cable Wyrestorm HDBaseT extenders offer incredible flexibility and stability of signal distribution combined with innovative features and an ease of use that provides solutions where stable HD transmission and control over distance is required whilst also eliminating the need for additio...

Page 3: ...d in any way especially at plug connections 7 Only use attachments accessories specified by the manufacturer 8 Units contain non servicable parts Refer all servicing to qualified service personnel WARNING To reduce the risk of fire electric shock or product damage 4 Technical Support support wyrestorm com US 866 677 0053 EU 44 0 1793 230 343 Reads and copies EDID from connected devices with additi...

Page 4: ...orm RECEIVER 1 x Printed installation guide also downloadable from website product page 2 x pairs of mounting brackets 1 x 12vDC power supply 1 x wide band IR TX Emitter small round for attachment to Input device 1 x wide band IR RX Receiver larger rectangular for attachment to Display IR frequency range 30KHz to 56KHz 1 2 3 4 5 7 6 8 10 9 11 RS232 Port HDMI Input with LED Active Signal Indicator ...

Page 5: ...ndicator Lit for active Duplicate HDMI output with LED Active Signal Indicator Lit for active EDID DIP Switch with Upgrade Switcher TCP IP Connector IR TX Transmitter port IR RX Receiver port LED HDBT Link Indicator Lit for active RS232 Port LED HDBT Link Indicator Lit for active HDBT IN LED Power Indicator Lit for active HDMI output TCP IP Connector IR TX Transmitter port IR RX Receiver port HDBT...

Page 6: ...ix with the adhesive backing You may need to adjust the location of the emitter later to achieve the best results Sometimes moving the sensor to a different area on the source facia can improve IR performance Insert the IR emitter 3 5mm jack into the IR TX port on the TRANSMITTER Tip You can locate the infrared sensor by shining a flashlight onto the facia of most devices For two way IR to control...

Page 7: ...l not effect setting Note 1 Copy EDID from detected sink to unit with DIP switch set to this position Note 2 Set embedded 1080p stereo 3D compatible EDID with DIP switch set to this position Note 3 Set embedded 1080P stereo EDID with DIP switch set to this position Note 4 Set embedded 1080i stereo EDID with DIP switch set to this position Note 5 Set embedded 1080P 5 1 EDID with DIP switch set to t...

Page 8: ...dimensions are approximate 100m 328ft 12VDC 0 86kg 1 87lbs Each Each Mass Per Main unit sync sync 17 Watts Max Pairs with EX 1UTP IR 100 POH Transmitter 145mmWx106mmDx29mmH 5 71 Wx4 17 Dx1 14 H Transmitter 130mmWx106mmDx29mmH 5 11 Wx4 17 Dx1 14 H Receiver 100m 328ft 1 Carefully open the case of the EX 1UTP IR 100 POH Receiver On the edge of the circuit board are positioned two jumper caps to chang...

Page 9: ...Power is only need on EX 1UTP IR 100 EDID Power is only need on EX 1UTP IR 100 EDID 5VDC 12vdc POWER 5VDC 12vdc POWER 5VDC 12vdc POWER 2 Gently move the jumper caps to the Update position to allow upgrade through the RS232 port 3 Connect USB Serial Cable to PC and run VS100 RX Firmware Update batch file 4 Once update has been completed be sure to return the jumper caps to the Normal position for R...

Page 10: ...be charged for the repair of any unit received unless such information is provided Should you feel your product does not function adequately due to defects in materials or workmanship we referred to as the warrantor will for the length of the period indicated below starting from the original date of purchase either a Repair the product with new or refurbished parts or b Replace it with a new or re...

Page 11: ...nty For example damages for lost time the cost of having a person persons remove or re install previously installed equipment travel to and from service location loss of or damage to media images data or other recorded stored content The items listed here are not exclusive but are for illustration only Parts and service not covered by this limited warranty are not the responsibility of the warrant...

Page 12: ... 0053 UK 44 0 1793 238 338 Email support wyrestorm com We reserve the right to change specification or product dimensions at any time 1 1 866 677 0053 www wyrestorm com WyreStorm Offices US Office 6991 Appling Farms Parkway Suite 104 Memphis TN 38133 Tel 901 384 3575 Fax 901 384 3574 Unit 22 Ergo Business Park Swindon Wiltshire SN3 3JW UK Tel 44 0 1793 230 343 Fax 44 0 1793 230 583 WyreStorm Techn...