10
Always start the engine with the pump in the bypass mode.
Rotate the blue bypass handle counterclockwise to put the
pump in the bypass mode.
Starting procedures will vary for different engines (see en
-
gine owner’s manual). The Honda manual start engine is
very popular on the Wylie Power Sprayers. Turn the engine
switch “on” before pulling the rope to start the engine.
If chemicals need further mixing in the tank, open the
agitator ball valve.
Operation
Once the chemical is thoroughly mixed, close the agita
-
tor valve. Remove the trigger gun from the storage frame
and unroll a sufficient length of pressure hose. Open the
pressure hose ball valve.
Change the pump from bypass mode to pressure mode by
rotating the blue handle clockwise.
Adjust the pressure by turning the pressure adjustment
knob. Screw the knob “in” to increase pressure, “out” to
decrease pressure. The maximum pressure built by the
CDS/John Blue diaphragm pump in 580 psi. Do not set
the pressure above 600 psi.
Figure B5
Honda Engine Start Switch
Figure B4
Bypass Valve
Figure B6
Open Agitator Ball Valve
Figure B7
Open Pressure Ball Valve
Figure B8
Change To Pressure Mode By Rotating Clockwise
Summary of Contents for Power Sprayer Series
Page 4: ......
Page 30: ...26 Notes Notes...