background image

EM

ergency 

S

top knob 

is popped out. 

(Twisting 

clockwise restores  

all functions) 

Chargers are unplugged. 

(Drive will not operate 

while charging)

Both wheels are locked. 

(Must be locked to drive)

PRELIMINARY / SETUP

CONTROLS

Before operating the DENALI, verify that:

Includes two handests

SAFETY

JOYSTICK

Horn

Battery 

Status

Power 

Button

Joystick

CHARGING

BATTERY

Plug charger 

jack into 

battery and 

AC plug into 

outlet

52360-R01

800.255.3126 | wyeastmedical.com

DENALI

600

Instructions For Use

EM

ergency 

S

top

 

(Push to stop all functions

Twist clockwise to restore) 

Manual 

EM

ergency 

Lowering of Sling Bar 

(Turn handle counter-

clockwise to lower  

sling bar) 

Powered 

EM

ergency 

Lowering of Sling Bar

 

(Push in black button to 

lower sling bar)

PENDANT

Forward/Reverse

Push FORWARD-

REVERSE button 

C

 

until wheels point 

forward

Sideways

Push SIDEWAYS 

button 

H

 until 

wheels point 

sideways

Rotationally

Push the apt WHEEL 

ANGLE button 

C

 

or 

H

 until the 

wheels are at the 

needed angle

Sling Bar Position

Lift Arm Position

Bar & Arm Together

Leg Width Adjust

Wheel Angle 

Push and hold RAISE or 

LOWER button 

D

to 

position the sling bar

B

C

E

F

D

H

Push and hold RAISE or 

LOWER button 

E

    to 

position the lift arm

Push and hold RAISE or 

LOWER button 

F

 to 

position the lift bar & 

arm simultaneously

Push and hold CLOSE 

or OPEN button 

B

 

to spread lift legs to 

needed width 

Summary of Contents for DENALI 600 52300

Page 1: ... Lowering of Sling Bar Turn handle counter clockwise to lower sling bar Powered EMergency Lowering of Sling Bar Push in black button to lower sling bar PENDANT Forward Reverse Push FORWARD REVERSE button C until wheels point forward Sideways Push SIDEWAYS button H until wheels point sideways Rotationally Push the apt WHEEL ANGLE button C or H until the wheels are at the needed angle Sling Bar Posi...

Page 2: ...Position Wheel Angle C All Yellow Areas on Equipment Are Adjustable Be sure charger is unplugged from battery wheels are locked and Emergency Stop is not activated Pendant Functions Power Functions Adjust Console Height Joystick Removed from console Sling Bar Position Lift Arm Position Bar Arm Together Leg Width Adjust Wheel Angle 3 4 6 7 5 8 Press Power Button To Power Drive On Press Any Button O...

Page 3: ...Page 1 of 16 52363 R02 OPERATOR S MANUAL DENALI 600 PATIENT LIFT Model No 52300 52400 ...

Page 4: ...efect and to determine whether any damage was caused by neglect misuse unauthorized alteration or failure to follow maintenance instructions With respect to a claim covered by this warranty the defective part will be replaced or repaired at no charge provided the defective part is returned to Wy East Medical The user has the responsibility for shipping charges and installation Assistance is availa...

Page 5: ... OPERATING THE DENALI 600 PATIENT LIFT 7 SAFETY FEATURES 7 SLING USAGE 8 PREPARING TO USE 8 DRIVING FUNCTION 9 LIFTING FUNCTION 11 BATTERY FUNCTION 12 OXYGEN TANK IV POLE HOLDER optional 12 PERIODIC MAINTENANCE 13 FACTORY ASSISTANCE 13 REPLACEMENT PARTS 13 RETURNING ITEMS 13 SPECIFICATIONS 14 TROUBLESHOOTING 15 CONTACT INFORMATION 16 ...

Page 6: ...nderstood please contact your supplier for more details Failure to comply with warnings in this manual may result in injury Keep this manual with the Denali 600 Patient Lift and refer to it as required Contents of this manual are subjected to change without prior notice to users DEFINITIONS The words WARNING CAUTION and NOTE carry specific meanings and should be carefully reviewed WARNING The pers...

Page 7: ...euverability in tight spaces Intended for use in acute care long term care outpatient care and home care It is not recommended for use in a shower or wet environment Prior to using the Denali 600 for transfer or any other procedure the patient must be assessed by a qualified professional to determine the suitability of using the Denali 600 with that patient Cables need to be fixed to the applicati...

Page 8: ... 9 For cleaning and disinfection use a 5 chlorine bleach dilution and an EPA registered Hard Surface Disinfectant on painted and plastic surfaces On all other surfaces use an EPA registered Hard Surface disinfectant wipe that does not contain sodium hypochlorite bleach 10 Warranty applies only if repairs or alterations are done by an authorized technician PRIOR TO FIRST USE The battery will be ful...

Page 9: ...trol handset or the POWERED EMERGENCY LOWERING does not function Slack in the sling bar strap All lift arm and sling bar movement functions are disabled if excessive slack is present in the sling bar strap Apply tension to the sling bar strap to restore all function Twist in the sling bar strap The lift arm can only be raised and the sling bar can only be lowered if the sling bar strap is twisted ...

Page 10: ...e other and slide the console to the desired position Release the lock knob to secure The drive control joystick and the lift control handset can be removed from their cradles for ease of use around the lift To use drive functions both wheel locking levers must be in the down position to lock the wheels Move the locking levers up to unlock the wheels in order to manually move the lift It is recomm...

Page 11: ...he two vertical lights indicate drive wheel orientation forward reverse or sideways drive The lift control handset controls the orientation of the drive wheels Push the buttons to position the drive wheels for the desired direction of travel Refer to the instructions below Push button to move wheels for forward reverse driving Push button to move wheels for rotational driving Push button to move w...

Page 12: ...the instructions below Push button to move legs closed Push button to move legs open To drive and steer move the speed and direction knob on the joystick The more the knob is moved in a given direction the faster the speed in that direction i e moving the knob all the way forward achieves the fastest speed in that direction Leg position control buttons ...

Page 13: ...ns below Push buttons to move the sling bar up or down Push buttons to move the lift arm up or down The sling bar remains in its position Push buttons to move the lift arm and sling bar together up or down Lift arm position control buttons Sling bar position control buttons Sling bar and lift arm position control buttons ...

Page 14: ...harge the battery plug the AC power cord into an outlet and the battery cable into the battery The battery may be charged while on the lift or removed from the lift A full charge takes 10 hours A quick charge takes 2 hours Pull the battery charger straight out to remove it from the Velcro retainer on the lift OXYGEN TANK IV POLE HOLDER optional Socket for standard diameter IV pole Rotate the oxyge...

Page 15: ...erform load testing EVERY 2 YEARS Replace the sling bar strap WARNING No unauthorized modification of this equipment is allowed Contact Wy East Medical prior to any modification of this equipment FACTORY ASSISTANCE REPLACEMENT PARTS To order replacement parts contact Wy East Medical customer service or your Wy East representative Include the following information with your request The serial numbe...

Page 16: ...28 Turning Diameter 53 Driving Speed 1 4 mph Lift 15 85 Intermittent Usage Run 2 min Continuous Off 18 min Drive 50 50 Intermittent Usage Run 10 min continuous Off 10 min Emergency Lowering Electrical and Manual Operating Environmental Conditions Temperature 5 C to 40 C Relative Humidity 20 to 90 30 C non condensing Atmospheric Pressure 700 to 1060 hPa Storage Environmental Conditions Temperature ...

Page 17: ...er is connected to battery Disconnect charger from battery Sling bar will not raise or lower Slack in sling bar strap Remove slack in strap Bad actuator or controls Contact Wy East for service Sling bar will not raise Twist in sling bar strap Remove twist in strap Lift arm will not raise or lower Slack in sling bar strap Remove slack in strap Bad actuator or controls Contact Wy East for service Li...

Page 18: ...Page 16 of 16 52363 R02 CONTACT INFORMATION Wy East Medical Corporation P O Box 1625 Clackamas OR 97015 USA 503 657 3101 800 255 3126 FAX 503 657 6901 www wyeastmedical com contact wyeastmedical com ...

Reviews: