WIRELESS CONNECTIVITY & SENSORS
User manual Thyone-I
7.5. Manage the device state
7.5.1. CMD_START_IND
This is an indication message that the module sends to the host micro-controller on boot-up in
command mode. This message indicates that the module has successfully boot-up and ready
to receive commands from the host.
Format:
Start signal
Command
Length
Reset reason
Module mode
CS
0x02
0x73
0x03 0x00
1 Byte
1 Byte
1 Byte
1 Byte
Reset reason:
0x01:
Power on
0x02:
Pin reset
0x04:
Soft reset
0x06:
Wake up from sleep
Others:
Reserved
Module mode:
0x01:
Application
0x05:
Test mode
Other:
Reserved
7.5.2. CMD_GETSTATE_REQ
This command returns the current state of the module.
Please refer to chapter
for details on the states of the module.
Format:
Start signal
Command
Length
CS
0x02
0x01
0x00 0x00
0x03
Response (
Order code 2611011021000
49