WIRELESS CONNECTIVITY & SENSORS
User manual Thyone-I
Status byte
Description
0x00
Requested action success
0x01
Requested action failed (Parameter(s) out of bound
or Invalid request packet)
0x02
Module is busy with a on-going RF operation.
Request cannot be processed
0x03
Error occured while triggering the requested
operation
0x04
Key not found
0xF5
Supply voltage too low
0xFF
Operation not permitted in the current state
Table 14: Confirmation status byte
Host integration example codes for checksum calculation and command frame
structure can be found in annex
and
, as well as in the
If the transmission of the UART command has not finished within the packet
transmission duration (depending on the currently selected UART Baud rate +
5ms after having received the start signal), the module will discard the received
bytes and wait for a new command. This means that the delay between 2
successive bytes in a frame must be kept as low as possible.
7.3. User data commands
In this section, the commands available to transmit and receive user data are described in
detail.
7.3.1. CMD_BROADCAST_DATA_REQ
This command provides the simple broadcast data transmission. A payload length of maximum
224 bytes can be transmitted per packet.
When the data is processed by the module a
is output on the UART. Additionally
a
will follow as soon as the data has been transmitted over the air.
The receiving Thyone-I will get a
message containing the transmitted payload
data.
Format:
Start signal
Command
Length
Payload
CS
0x02
0x06
2 Bytes
Length Bytes
1 Byte
Order code 2611011021000
42