FRIGOLINK

1.3.2 Output 

circuit 

diagram

Fig. 4: ANI-1F1 - output wiring diagram

Digital outputs (relays) K 1 - K 14

11

12 13 14

71 72 73 74

81 82 83 84

238 237 236 235 234 233 232 231

250 249 248 247 246 245 244 243 242 241

201 202 203 204 205 206 207 208 209 210

211 212 213 214 215 216 217 218 219 220

221 222 223 224 225 226 227 228 229 230

44 43 42 41

151 152 153 154 155 156 157 158 159 160

194 193 192 191

190 189 188 187 186 185 184 183 182 181

180 179 178 177 176 175 174 173 172 171

170 169 168 167 166 165 164 163 162 161

98 99

140 139 138 137 136 135 134 133 132 131

120 119 118 117 116 115 114 113 112 111

130 129 128 127 126 125 124 123 122 121

110 109 108 107 106 105 104 103 102 101

µC

RS 485

PE

11

14

F-BUS

LAN

71

F-BUS

74

C-BUS

C-BUS

C-BUS

81

84

250

Uout 5...1 / 0-10V

241

V 4...1 / each 60VA max.

238

231

K 5...9 / each 4(2)A@230V~

211

201

210

K 1...4 / each 4(2)A@230V~

220

K 10...14 / each 4(2)A@230V~

221

230

S16

194

S 15...11 / Sensor

190

191

181

S 10...6 / Sensor

180

171

170

S 5...1 / Sensor

161

Iin 1...5 / 4-20mA

160

151

Uin 2, 1 / 0-10V

44

41

0-10V

GND

0-10V

GND

24V=

4-20mA

207,209
211,213
215,217
219,221
223,225
227,229

208,210
212,214
216,218
220,222
224,226
228,230

202,205 203,206

231,233
235,237

232,234
236,238

241,243
245,247
249

242,244
246,248
250

201,204

44,42

43,41

152,154
156,158
160

151,153
155,157
159

Relay

K 3-14

Relay

K1,K2

Solid State

Relay V 1-4

0-10V

Analog Output

Uout 1-5

0-10V

Analog Input

Uin 1, 2

4-20mA

Analog Input

Iin 1-5

Digital Inputs

DI 1-20

230V~/50Hz

140
130

N 20...11 / neutral terminal

DI 10...1 / 230V~

120
110

131
121

111

101

DI 20...11 / 230V~

N 10...1 / neutral terminal

N

230V~

101-110
121-130

111-120
131-140

max. 20VA

ANIMUS    ANI-1F1

part of Frigolink

7C451061A

7A4510610

7B451061A

250

Uout 5...1 / 0-10V

241

V 4...1 / each 60VA max.

238

231

K 5...9 / each 4(2)A@230V~

211

201

210

K 1...4 / each 4(2)A@230V~

220

K 10...14 / each 4(2)A@230V~

221

230

0-10V

GND

207,209
211,213
215,217
219,221
223,225
227,229

208,210
212,214
216,218
220,222
224,226
228,230

202,205 203,206

231,233
235,237

232,234
236,238

241,243
245,247
249

242,244
246,248
250

Relay

K 3-14

Relay

K1,K2

Solid State

Relay V 1-4

0-10V

Analog Output

Uout 1-5

201,204

238 237 236 235 234 233 232 231

250 249 248 247 246 245 244 243 242 241

201 202 203 204 205 206 207 208 209 210

211 212 213 214 215 216 217 218 219 220

221 222 223 224 225 226 227 228 229 230

Terminal

Digital output

Contact arrange-
ment

Assignment

201

Changeover contact 
K 1/ 
4(2)A@230V~

COM

Alarm output Prio 1

202

MT

203

NO

204

Changeover contact 
K 2 /
4(2)A@230V~

COM

Alarm output Prio 2

205

MT

206

NO

207

NO contact K 3 /
4(2)A@230V~

COM

MT compressor 1 - 
release FC

208

NO

209

NO contact K 4 /
4(2)A@230V~

COM

MT compressor 2 - 
mains contactor

210

NO

211

NO contact K 5 /
4(2)A@230V~

COM

MT compressor 3 - 
mains contactor

212

NO

213

NO contact K 6 /
4(2)A@230V~

COM

LT compressor - ena-
ble or mains contac-
tor (selectable)

214

NO

215

NO contact K 7 /
4(2)A@230V~

COM

MP too low (gas 
cooler bypass)

216

NO

217

NO contact K 8 /
4(2)A@230V~

COM

HR VALVE

218

NO

219

NO contact K 9 /
4(2)A@230V~

COM

HR pump

220

NO

Summary of Contents for FRIGOLINK ANI-1F1

Page 1: ...gas temperature Oscillation protection function Blocking time after compressor fault Two step load shedding and fast return flow Operating hours counter for each compressor Low temperature compressor...

Page 2: ...rcuit diagram 5 Digital inputs DI 1 DI 20 5 Analogue inputs Uin 1 2 6 Analogue inputs Iin 1 Iin 5 6 Analogue inputs S 1 S 16 7 1 3 2 Output circuit diagram 8 Digital outputs relays K 1 K 14 8 Digital...

Page 3: ...intended purpose Warnung WARNING DANGER TO LIFE FROM ELECTRIC SHOCK AND OR FIRE Switch off the power to the entire plant when installing wiring or removing Otherwise a mains voltage and or external v...

Page 4: ...58 160 151 153 155 157 159 Relay K 3 14 Relay K1 K2 Solid State Relay V 1 4 0 10V Analog Output Uout 1 5 0 10V Analog Input Uin 1 2 4 20mA Analog Input Iin 1 5 Digital Inputs DI 1 20 230V 50Hz 140 130...

Page 5: ...1 5 0 10V Analog Input Uin 1 2 4 20mA Analog Input Iin 1 5 Digital Inputs DI 1 20 230V 50Hz 140 130 N 20 11 neutral terminal DI 10 1 230V 120 110 131 121 111 101 DI 20 11 230V N 10 1 neutral terminal...

Page 6: ...ult PSL LP com pound 136 N 127 DI 17 230V Fault HP compound 137 N 128 DI 18 230V Fault in GC fan 1 138 N 129 DI 19 230V UPS fault 139 N 130 DI 20 230V Fault RC protection 140 N Terminal Analogue input...

Page 7: ...S 3 DGF Pressure gas temper ature LT compressor desuperheating 167 168 S 4 TRK External temperature 169 170 S 5 DGF Temperature gas cooler outlet T GK 1 171 172 S 6 DGF Temperature gas cooler outlet T...

Page 8: ...Output Uout 1 5 0 10V Analog Input Uin 1 2 4 20mA Analog Input Iin 1 5 Digital Inputs DI 1 20 230V 50Hz 140 130 N 20 11 neutral terminal DI 10 1 230V 120 110 131 121 111 101 DI 20 11 230V N 10 1 neut...

Page 9: ...output SSR Contact arrange ment Assignment 231 Semiconductor V 1 4 60VA 230V NO MT HG bypass valve suction gas monitor ing 232 COM 233 Semiconductor V 2 4 60VA 230V NO Post injection MT 234 COM 235 Se...

Page 10: ...each 4 2 A 230V 211 201 210 K 1 4 each 4 2 A 230V 220 K 10 14 each 4 2 A 230V 221 230 S16 194 S 15 11 Sensor 190 191 181 S 10 6 Sensor 180 171 170 S 5 1 Sensor 161 Iin 1 5 4 20mA 160 151 Uin 2 1 0 10...

Page 11: ...tage is switched off Top hat rail installation 1 There are 2 fastening catches located on the back of the module A Press both catches a downward until they engage with a click 2 There are 4 retaining...

Page 12: ...ting voltage green fault red 4 x LED green CAN bus data traffic CAN Tx CAN Rx Sensors 16 x DGF TRK Communication C BUS 3 wire CAN bus interface shielded galvanically isolated screw terminals 2 5mm2 an...

Reviews: