Target group

The meter was developed for work in the field and in the laboratory. 
Thus, we assume that, as a result of their professional training and 
experience, the operators will know the necessary safety precautions 
to take when handling chemicals.

The personnel responsible for the commissioning, operation and 
maintenance must have the necessary qualifications for this work. If the 
personnel do not have the required skills they have to be instructed. 
Furthermore, it must be ensured that the personnel read and 
completely understand the present operating manual.

Safety instructions

Safety instructions point out dangers:

Caution

indicates instructions that must be followed precisely in order to 
avoid the possibility of slight injuries or damage to the instrument 
or the environment.

Safe operation

Caution

Danger of eye damage by visible and invisible LED radiation. In 
the cell shaft of the Turb 430 IR there are light emitting diodes 
(LED) of the 1M class. Do not look at the radiation using optical 
instruments. With normal, authorized use there is no hazard.

Display and socket field

Display

The graphic display shows all information of the current measurement 
in the measured value display. The illumination enables to read the 
display even in the darkness. 

Measured value (with unit)

Status line with date and time

Turbidity

157.0

 

FNU
NTU

01.02.05 15:12

Summary of Contents for WTW Turb 430 IR

Page 1: ...BEDIENUNGSANLEITUNG ba75507d04 11 2018 Turb 430 IR T TASCHENTURBIDIMETER...

Page 2: ...kter Form die Beschreibung aller Grundfunktionen alle Hinweise f r den sicheren Betrieb und alle technischen Daten Eine ausf hrlichere Beschreibung mit Hinweisen f r besondere Anwendungen erhalten Sie...

Page 3: ...a 14 Turbidity Turb 430 IR 16 Turbidity Turb 430 T 16 Note Part of the process of consequently improving our products is the continuos further development of instrument firmware All current data for t...

Page 4: ...ting manual Safety instructions Safety instructions point out dangers Caution indicates instructions that must be followed precisely in order to avoid the possibility of slight injuries or damage to t...

Page 5: ...ntains basic information on the operation of the Turb 430 IR T Operating modes Measurement The display indicates measurement data in the measured value display Calibration The display indicates a cali...

Page 6: ...edures contain further submenus The selection is made with the keys The current selection is displayed in reverse video Menus The name of the menu is displayed at the upper edge of the frame Switch to...

Page 7: ...TER Example Functions Functions are designated by the name of the function They are immediately carried out by confirming with START ENTER Example display the Calibration record function in the Turbid...

Page 8: ...To be able to insert cells in the Turb 430 IR T the cell shaft has to be prepared to take in a cell i Insert standard 1000 FNU NTU i Press and hold START i Align sample Turbidity Calibration The i ind...

Page 9: ...cell see below 1 Clean the cell 2 Insert the cell 3 Align the cell Press and hold the START ENTER key Slowly and in small steps rotate the cell by one complete rotation by 360 After each step wait fo...

Page 10: ...lack light protection cap 1 Rinse out a clean cell with the sample to be measured Pour approximately 10 ml sample into the cell Close the cell and rotate it several times before throwing the sample aw...

Page 11: ...free The only maintenance task is replacing the batteries or accumulator pack Caution Make sure the poles of the batteries are the right way round The signs on the batteries must correspond to the si...

Page 12: ...ge the optical characteristics of the cell and falsify the measured value For this reason never use scratched cells 1 Open the battery compartment Unscrew the two screws 1 on the underside of the mete...

Page 13: ...ries Charge the accumulator pack Cause Remedy Software error Operating condition undefined or EMC load unallowed Processor reset Press the START ENTER and PRT key simultaneously Cause Remedy Instrumen...

Page 14: ...Operating time with battery operation Turb 430 IR approx 3000 measurements Turb 430 T approx 2000 measurements Accumulator pack optional 5 x 1 2 V nickel metal hydride NiMH type AAA Power pack Chargin...

Page 15: ...digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment...

Page 16: ...red value or 0 01 FNU NTU Reproducibility 0 5 of the measured value Response time 4 seconds Calibration Automatic 3 point calibration Measuring principle Nephelometric measurement according to US EPA...

Page 17: ......

Page 18: ...buildings factories and farms In more than 150 countries we have strong long standing relationships with customers who know us for our powerful combination of leading product brands and applications...

Reviews: