Warnings and Cautions:

Installation Instructions

Secure Racking

If Secure Racked units are installed in a closed or multi-unit rack assembly, they may require further 

evaluation by Certification Agencies.  The following items must be considered.
1.  The ambient within the rack may be greater than room ambient.  Installation should be such 

that the amount of air flow required for safe operation is not compromised.  The maximum 

temperature for the equipment in this environment is 60°C.  Consideration should be given to the 

maximum rated ambient.

2.  Installation should be such that a hazardous stability condition is not achieved due to uneven 

loading.

Input Supply

1.  Check nameplate ratings to assure there is no overloading of supply circuits that could have an 

effect on overcurrent protection and supply wiring.

2.  When installing 48 VDC rated equipment, it must be installed only per the following conditions:

A.  Connect the equipment to a 48 VDC supply source that is electrically isolated from the 

alternating current source.  The 48 VDC source is to be connected to a 48 VDC SELV source.

B.  Input wiring to terminal block must be routed and secured in such a manner that it is 

protected from damage and stress.  Do not route wiring past sharp edges or moving parts.

C.  A readily accessible disconnect device, with a 3 mm minimum contact gap, shall be 

incorporated in the fixed wiring.

Grounding

Reliable earthing of this equipment must be maintained.  Particular attention should be given to 

supply connections when connecting to power strips, rather than direct connections to the branch 

circuit.

No Serviceable Parts Inside; Authorized Service Personnel Only

Do not attempt to repair or service this device yourself.  Internal components must be serviced by 

authorized personnel only.

•  Shock Hazard - Do Not Enter
•  Lithium Battery 

CAUTION:  Danger of explosion if battery is incorrectly replaced.  Replace only with same 

or equivalent type recommended by the manufacturer.  Discard used batteries according to the 

manufacturer's instructions.

Disconnect Power

If any of the following events are noted, immediately disconnect the unit from the outlet and contact 

qualified service personnel:
1.  If the power cord becomes frayed or damaged.
2.  If liquid has been spilled into the device or if the device has been exposed to rain or water.

Modem Cables

CAUTION:  To reduce the risk of fire, use only No. 26 AWG or larger (e.g., 24 AWG) UL Listed or 

CSA Certified Telecommunication Line Cord.

Summary of Contents for RMM Series

Page 1: ...WTI Part No 14517 Rev A RMM Series RackMountModems Quick Start Guide...

Page 2: ...outed and secured in such a manner that it is protected from damage and stress Do not route wiring past sharp edges or moving parts C A readily accessible disconnect device with a 3 mm minimum contact...

Page 3: ...0V AC power DC powered RMM units can be connected to 18 to 72 Volt DC power When power is applied to the RMM the Input Power A and Input Power B indicators should light Note that the presence of two p...

Page 4: ...1 9 1 2 3 4 5 6 7 8 9 DCD TXD RXD RTS CTS DTR GND DSR R R R T T T GND T X DCE RMM 1 8 1 2 3 4 5 6 7 8 RTS DTR RXD TXD DCD CTS GND GND R R R T T T GND DCE RMM 1 6 1 2 3 4 5 6 Not Used Not Used RING No...

Page 5: ...pears select Serial and then select the COM port that has been used to connect to the RMM 3 Enter the appropriate AT commands to change the desired parameter s Note that the AT prefix must preceed eac...

Page 6: ...e Only one Modem Port can be connected at a time DB25F Modem Port Use a standard DB25 Modem Cable For a description of the port pinout see Figure 1 DB9F Modem Port Use a standard DB9 PC to Modem cable...

Page 7: ...operation WARNING Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment EMC and Safety Directiv...

Page 8: ...5 Sterling Irvine California 92618 949 586 9950 Toll Free 1 800 854 7226 Fax 949 583 9514 http www wti com western telematic inc TM...

Reviews: