=UTGU\T# %?fUbfYUg
!!"
=UTGU\T# %?`UbQd_bµc7eYTUD)## "
= #" "%1`bY\" "
The image table used by the DeviceNet module is provided in
“Discrete Integration” on page 3-5.
&RPELQDWLRQ
0RGXOH
The combination module is used to provide additional discrete
(local) inputs and outputs for either remote I/O or for DeviceNet
integration. These inputs and outputs are provided to allow for
direct control of critical local and safety interlocks.
>?D5*
This module is NOT required when discrete integration is used for the
3005, because all I/O are directly controlled under the DIO integration
scheme.
Descriptions of the I/O provided by this module appear in
“Local and Safety I/O” on page 3-1.
83
Slave device is returning error
responses when module attempts to
communicate with it (node number
alternately flashes).
Check accuracy of Scan List table entry.
Check slave device configuration.
84
Module is initializing the DeviceNet
channel.
None. This code clears itself once the
module attempts to initialize all slave
devices on the channel.
85
Data size returned is bigger than
expected.
Check accuracy of Scan List table entry.
Check slave device configuration.
88
Not an error. At power-up and reset, the
module displays all 14 segments of
these LEDs.
None.
90
User has disabled the communications
port.
Reconfigure your module.
91
Bus-off condition detected on the
communications port. Module is detect-
ing communication errors.
Check the DeviceNet connections and
physical media integrity. Check system
for failed slave devices or other possible
sources of network interference.
92
No network power detected on com-
munications port.
Provide network power. Make sure that
module drop cable is providing network
power to module communications port.
95
Application FLASH update in progress.
None. Do not disconnect the module
while application FLASH in progress.
You will lose any existing data in the
module’s memory.
97
Module halted by user command.
None.
98
Unrecoverable firmware failure.
Service or replace module.
99
Unrecoverable hardware failure.
Service or replace module.
Code
Description
Remedy
Summary of Contents for MedWeld 3005
Page 2: ...YY UTGU T UbQd_bµc 7eYTU V_b D 1 bY ...
Page 84: ...3_ e YSQdY_ c Q T 9 UTGU T UbQd_bµc 7eYTU D 1 bY ...
Page 110: ...GU T CSXUTe Uc UTGU T UbQd_bµc 7eYTU D 1 bY ...
Page 126: ...1TfQ SUT C_VdgQbU 6UQdebUc UTGU T UbQd_bµc 7eYTU D 1 bY ...
Page 144: ...CUde QbQ UdUbc UTGU T UbQd_bµc 7eYTU D 1 bY ...