25
RECEIVING BURSTS
Once your system is setup you should always verify reception by
transmitting a self test burst from a 406 MHz beacon.
All bursts that are received are logged and recorded. When a burst
is a Normal Mode (Live Burst) the 15 Hex ID will be shown in red
(see Index item #2 below).
Visual Alarm
Normal Mode
(Live Burst)
reception
NOTICE!
All Normal Mode bursts have the potential of being received by the
satellites causing a false alert. If you are confident that a Normal Mode
burst is definitely a false alert and has sufficient power to be received
by the satellites, then contact your local Mission Control Center (MCC).
Refer to the MCC list on page 32 of this Manual.