Installation & Operation Manual
Wall Mounted- Outdoor Drinking Fountain
WODF-2WM Series
Willoughby Stainless Fountains
TOLL FREE
(800) 428-4065
● LOCAL
(317) 875-0830
● FAX
(317) 875-0837
Page 8
Rev. 11/2019
www.willoughbystainlessfountains.com
Installation Instructions
Step 1: Fixture Installation
Note: The WODF outdoor drinking fountain Is to be mounted on a flat, suitably level
surface (wall, concrete or otherwise) with an adequate support structure.
Note: Refer to the Physical / Rough-In Dimensions for locating fixture mounting
points and plumbing connections.
1�)
Install service shut-off valve in water supply line (valve not furnished).
2�)
Locate and complete the rough-in mounting holes and plumbnig access hole as specified.
3�) Install the drinking fountain wall mounting plate using hardware supplied by others�
4�)
Once the wall mounting plate have been attached, mount the fixture by placing it on the
mounting plate. Secure the fixture to the plate with the security screws provided.
5�)
Make sure that the positioned fixture is level, both front to back and side to side, to ensure
proper draining. Adjust as necessary, then fully tighten the nuts to secure the fixture.
6�)
As noted previously, flush the water supply line with clean drinking water before making final
connections to the drinking fountain�
7�)
Connect water supply line to inline strainer inside the drinking fountain or bottle filler using 3/8"
plastic tubing (extra tubing not furnished). Push tube straight into fitting on filter about 3/4" until it
reaches a positive stop� Water supply connection must comply with local codes�
8�) Connect the drain line to drainage system� Drain is to be 1-1/2" MIP minimum to a porous gravel
flll or main sewer line located below frost line. Installer to provide waste trap downstream of drain
connection� Drain and waste trap must comply with local codes�
9�) Turn on water supply and check both the water supply lines and drain lines for leaks�*
*For a Push Button flow adjustment, go to
Step 2