Installation & Operation Manual
Wall Mounted- Outdoor Drinking Fountain / Bottle Filler
WODF-1WM Series / CWBF-1WM Series
Willoughby Stainless Fountains
TOLL FREE
(800) 428-4065
● LOCAL
(317) 875-0830
● FAX
(317) 875-0837
Page 14
Rev. 3/2018
www.willoughbystainlessfountains.com
Troubleshooting- Fixture Plumbing
I�
Insufficient Flow
A. Ensure the service shut-off valve is fully open (provided by installer).
B�
Ensure water supply is within the normal operating range of 40-60 psi.
1�
If pressure is too low, flow can be drastically reduced.
2�
If pressure is too high, the strainer and/or valve may have been damaged.
3�
The unit is rated for a maximum range of 30-105 psi.
C�
Inspect the unit's valve for damage, and replace if necessary.
D�
Inspect the inline strainer for damage and/or clogging, and clean or replace as necessary.
E�
Check all fittings and tubing for damage and leaks. Replace components as necessary.
II�
Unit has problems draining
A. Remove and clean the drain screen.
B�
Remove any debris from the drain.
C�
Remove any debris from the PVC pipe and fittings.
D�
Check and clear the waste trap (provided by installer).