Page 44
Fig 41.1 Frame 6 Static Single Seal Face
•
Frame 6
o
Install two o-rings onto the seal housing.
o
Install the seal housing into the rotorcase.
o
Install o-ring over seal face
o
Install wave spring into housing
o
Install static seal face
o
Install C Clip
o
Alternatively put seal together on bench and install as unit
Seal Housing
C Clip
O-Ring
Wave
Spring
O-Ring
O-Ring
Static Seal Face
Summary of Contents for Revolution R0150X
Page 1: ...Installation Operation and Maintenance Manual for the Frame 6 7 ...
Page 54: ...Page 54 Rear Front 6 0 Specifications 6 1 Clearance Chart Radial Radial Hub Hub ...
Page 55: ...Page 55 Revolution CPP 808 ALLOY ...
Page 63: ...Page 63 ...