Wren 44 TurboProp Users Manual. Copyright Wren Turbines Ltd February 2008 Page 32
Problem Checklist
.
.
Symptom
Problem
Action
RX not switched on or RX battery
discharged
Verify connection and charge if
necessary
Display not connected properly
Ensure that display is connected and that
the plug ‘clicks’ into place
Display malfunction
Contact Wren
No reading on ECU display
unit
ECU problem
Contact Wren
Transmitter stick down/trim
up reads “StickLo”
Throttle channel needs reversing,
Reverse channel on Tx (most
Futaba’s need this)
Thermocouple not connected to
ECU
Verify connection
ECU problem
Contact Wren
Temp’ reading incorrect or
“0”
Thermocouple failure
Contact Wren
Temp’ reading shows lower
or negative figure when
gas lit
Thermocouple plug inserted wrong
way round
Ensure connector matches the label on
the ECU
Rpm sensor plug inserted incorrectly
Ensure connector matches the label on
the ECU
Rpm sensor lead broken/chafed
Contact Wren and remove source of
chafing
Rpm sensor malfunction
Contact Wren
No rpm indicated when
engine is spun
ECU problem
Contact Wren
Gas bottle empty/low/ very cold
Check gas flow by sound/smell,
replace or warn as necessary
Poor glow at plug
Check battery voltage
Plug blown
Replace plug
ECU battery low
Charge
Glow element not exposed
Tease out with pin
Gas will not ignite
Glow power insufficient
Go into “Glow plug power” screen on
ECU display and increase by 2
points
ECU shows “GlowBad”
Plug blown
Replace plug and check connections