World Precision Instruments

Each channel contains: a regulated DC power supply, 10V (+5 and –5V with respect 

to signal ground) to provide DC power to transducers and a precision differential 

amplifier with selectable voltage amplification and variable position adjustment 

control. Each module includes a low pass filter with conditioner for strain gauges and 

other transducers.

Unpacking

Upon receipt of this instrument, make a thorough inspection of the contents and 

check for possible damage. Missing cartons or obvious damage to cartons should be 

noted on the delivery receipt before signing. Concealed damage should be reported 

at once to the carrier and an inspection requested. Please read the section entitled 

“Claims and Returns” on page 15 of this manual. Please contact WPI Customer 

Service if any parts are missing at 941.371.1003 or [email protected].

Returns:

 Do not return any goods to WPI without obtaining prior approval (RMA 

# required) and instructions from WPI’s Returns Department. Goods returned 

(unauthorized) by collect freight may be refused. If a return shipment is necessary, 

use the original container, if possible. If the original container is not available, use a 

suitable substitute that is rigid and of adequate size. Wrap the instrument in paper or 

plastic surrounded with at least 100mm (four inches) of shock absorbing material. For 

further details, please read the section entitled “Claims and Returns” on page 15 of 

this manual.

Instrument Description

Single Channel Installation

1.  Remove two screws on the right and left sides of the instrument enclosure, 

respectively. Then remove eight screws on the bottom of the enclosure.

2.  Slide the internal chassis out of the enclosure.
3.  Remove the two screws holding the blank panel where the new channel is to be 

installed. 

4.  Plug the connector of this channel into the new module and then secure the 

channel in position with two screws.

5.  Slide the chassis into the enclosure and reinstall all screws.

Operations

Transducers are connected to Bridge-8 via the 8-pin transducer input connector on 

the front panel. Spare 8-pin DIN plugs are provided with each instrument to allow 

you to rewire the cables of other manufacturers’ transducers to connect to Bridge-8 

modules (Fig. 2).

Summary of Contents for Bridge-8

Page 1: ...WORLD PRECISION INSTRUMENTS ISDB ISO DAM 8A and BRIDGE8 Serial No _____________________ www wpiinc com INSTRUCTION MANUAL 060920...

Page 2: ......

Page 3: ...Output to Zero 3 Bridge Switch 3 Transducer Calibration 4 Example 4 General Amplification 4 Specifications 4 ISO DAM8A 6 Introduction 7 Notes and Warnings 7 Unpacking 7 Instrument Description 8 Noise...

Page 4: ...ii World Precision Instruments...

Page 5: ...on Fig 1 Up to eight rackmountable ISO DAM8A and Bridge8 modules can be combined in a single chassis Introduction Any combination of ISO DAM8A or Bridge 8 modules may be combined in the same instrumen...

Page 6: ...horized by collect freight may be refused If a return shipment is necessary use the original container if possible If the original container is not available use a suitable substitute that is rigid an...

Page 7: ...vel to nearly zero volts adjust the Offset Adjust knob above the Gain switch so that both lamps are lit together A significant increase in the sharpness or resolution of the zero adjustment may be ach...

Page 8: ...he output per mm Hg would be approximately 5 mV per mm Hg Since the nominal rating of 5 V per volt is usually not exact the user must in the end calibrate the transducer with a known hydrostatic press...

Page 9: ...arasota FL 34240 9258 USA As the manufacture distributor of the apparatus listed declare under sole responsibility that the product s WPI PN ISDB SERIES To which this declaration relates is are in con...

Page 10: ...at can cause damage to equipment Please read these carefully This symbol indicates a WARNING Warnings alert you to actions that can cause personal injury or pose a physical threat Please read these ca...

Page 11: ...set to 50 or 60 Hz and an output DC position adjustment The Iso DAM8 chassis can be ordered for either 110 120VAC or 220 240VAC operation The chassis can accommodate up to eight Iso DAM8A bioamplifier...

Page 12: ...he preparation and electrode lead wires in a Faraday cage or shield to reduce mains induction to sufficiently low levels It may be beneficial to extinguish overhead fluorescent lighting as well Use of...

Page 13: ...ust the Gain switch position stability This potentiometer is accessible through a small screwdriver hole on the front panel To adjust the DC balance connect the and inputs of the input connector or th...

Page 14: ...gly necessary if high gains are to be used with DC amplification The toggle switch below the DC Offset knob selects the polarity of the offset voltage If offset adjustment is not required the toggle s...

Page 15: ...rode i e TM33B01 EP2 Ag AgCl Half Cell Prep A B Central Ground 3294 Grounding Clip Fig 7 A typical single ended configuration is shown here The Iso DAM8A inputs can be connected in either differential...

Page 16: ...than a few inches from the amplifier inputs Even the use of shielded wires and proper grounding may be insufficient in a high electrical noise environment particularly if high impedance electrodes ar...

Page 17: ...erely distort some signals If a large DC offset is present in the setup the DC OFFSET control can be used to cancel it The setting of this control can be quite sensitive especially at high gain settin...

Page 18: ...14 World Precision Instruments...

Page 19: ...ecial or consequential arising from a failure of this product to operate in the manner desired by the user WPI shall not be liable for any damage to data or property that may be caused directly or ind...

Page 20: ...Tel 49 0 6031 67708 0 Fax 49 0 6031 67708 80 E mail wpide wpi europe com China Hong Kong WPI Shanghai Trading Co Ltd Rm 27A Liangfeng Building No 8 Dongfang Road Pudong New District Shanghai PR China...

Reviews: