5
Operation
1.To prolong your heating inductor, leaving an 5mm air gap between the coil and the work
piece is recommended as the insulation of the coil will eventually burn through if held directly
to hot material.
2.Choose the appropriately sized coil to give the closest fit to the work piece.
3.Insert both ends of the coil into the coil location socket and tighten the thumb screws
securely.
4.Activate the trigger to run the heating inductor for 1-3 minutes until enough heat has been
applied to the work piece to break the rust/corrosion bond.
5.Release the trigger and unplug the unit to turn the machine off.
6.Do not use portable generators. The unstable voltage will damage the unit and void the
warranty.
7.Turn unit off and allow the unit and all attachments to cool for at least 20 minutes. Handling
the unit or parts before they have cooled may result in injury.
8. Make sure the unit is turned off and unplugged. After cool enough, use a dry, clean, non-
abrasive cloth or paper towel to remove grease, oil, and other dirt from the heating inductor
and electrical lead before returning them to the storage case. Storage of unit while still hot may
result in damage to equipment or pose a fire hazard.
9.Press the trigger only when there is work piece inside the performed coil.
Warranty and Repairs
WOYO SMART CO.,LTD warrants the heating inductor and any parts thereof,
to be free from defects in materials for 18 months from the date of first
purchase, not including coils, when operated in accordance with the operating
and safety instructions manual.
This warranty is extended to the original purchaser, when proof of purchase is
provided.